Monitoring Parameter - Veikong VFD200A Series Operation Manual

High performance vector frequency inverter
Table of Contents

Advertisement

5-2 Monitoring parameter

U0 Group Basic monitoring parameter
function
Parameter name
code
U0-00 Running frequency
U0-01 Set frequency
U0-02 Bus voltage
U0-03 Output voltage
U0-04 Output current
U0-05 Output Power
U0-06 Output torque
U0-07 Input terminal status
U0-08 Output terminal status
U0-09 AI1 voltage
U0-10 AI2 voltage
U0-11 AI3 voltage
U0-12 Count value
U0-13 Length value
U0-14 Load speed display
U0-15 PID setting
U0-16 PID feedback value
U0-17 PLC stage
U0-18 Input pulse frequency
U0-19 Feedback speed
Remaining
U0-20
time
AI1
pre-correction
U0-21
voltage
AI2
pre-correction
U0-22
voltage
AI3
pre-correction
U0-23
voltage
U0-24 Line speed
U0-25 Current power-on time
U0-26 Current running time
U0-27 Input pulse frequency
U0-28 Communication setting
Encoder
U0-29
speed
U0-30 Main frequency X
Chapter 5 Function parameter
Display range
0.01~320.00Hz
0.0~3000.0V Display bus voltage (V)
0~1140V
0.0~6553.5A Display inverter output current (A)
0~32767kW
-200.0~200.0%
0~32767
0~1023
0.01V
0.01V
0.01V
0~65535
0~65535
0~65535
0~65535
0~65535
0~16
0.00~10.00kHz Display X6 input pulse frequency (kHz)
-320.0~+320.0
running
0.0~6500.0
Minutes
0.01~10.20V Display AI1 pre-correction voltage
0.01~10.20V Display AI2 pre-correction voltage
0.01~10.20V Display AI3 pre-correction voltage
0~65535m/Min The number of pulses per minute and
1Min
0.1Min
1Hz
0.01%
feedback
0.01Hz
0.01Hz
Instruction
Display operating frequency and set
frequency (Hz)
Display inverter output voltage (V)
Display inverter output power (kW)
Display inverter output torque during
operation
Input status: X1~X9 corresponds to
Bit0~Bit8
Output terminal status: Y2, relay,
Y1 corresponds to Bit0, Bit1, Bit3
Display input AI1 voltage (V)
Display input AI2 voltage (V)
Display input AI3 voltage (V)
Display count value
Display length value
Display load speed
Display PID settings
Display PLC operation phase
Display the actual output frequency of
the inverter Hz
Show remaining runtime
PB-07, calculate the line speed value
Display current cumulative power-on
time
Display PULSE input pulse frequency
Display communication settings
Display encoder feedback speed
Display main frequency X display
44
Communicat
ion address
7000H
7001H
7002H
7003H
7004H
7005H
7006H
7007H
7008H
7009H
700AH
700BH
700CH
700DH
700EH
700FH
7010H
7011H
7012H
7013H
7014H
7015H
7016H
7017H
7018H
7019H
701AH
701BH
701CH
701DH
701EH