5-1 Basic function parameter

P0 Basic function parameter
Function
Parameter Name
code
P0-00
GP type
Speed control mode
P0-01
selection
Run command source
P0-02
selection
Main frequency source
P0-03
X selection
Auxiliary frequency
P0-04
source Y selection
Frequency offset of
P0-05
auxiliary frequency
source for X operation
Frequency offset of
P0-06
auxiliary frequency
source for Y operation
Frequency source
P0-07
overlay selection

Chapter 5 Function parameter

Chapter 5 Function parameter
1:G (Constant torque load model)
2:P (Fan, pump type load model)
0:Speed sensorless vector control(SVC)
1:Speed sensor vector control(FVC)
2:V/F control
0: Operation panel command channel (LED
close)
1:Terminal command channel(LED open)
2: Communication command channel ( LED
Flashing)
0: Digital setting (non-retentive at power
failure)
1: Digital setting (retentive at power failure)
2:AI1
4: panel potentiometer
(X6)
6: Multi-segment instruction
7: Simple PLC
9: Communication given
Same as P0-03 (main frequency source X
selection)
0: relative to the maximum frequency
1: relative to the frequency source X
0%~150%
Ones place: frequency source selection
0: main frequency source X
1:
X
relationship determined by Tens position)
Setting Range
3:AI2
5: Pulse setting
8: PID
and
Y
operation
16
Default
1
2
0
1
0
0
100%