1-4. Setting of Internal Switches
1-4.
Setting of Internal Switches
PR-270/270A Board
PR-270/270A BOARD (A SIDE)
$1
Reh/AUX_TX
AUX RS-232C communicating function setting
Rech
Reh:
Outputs the R-Y/R/C signal supplied to the
CAMERA connector from R-Y/R/C connector.
(At normal use)
AUX_TX:
In the SDI mode, outputs the RS-232C signal
supplied to the CAMERA connector from
INTERCOM/TALLY/AUX connector. (At AUX
RS-232C communicating function use)
S2
Gch/AUX_RX
AUX RS-232C communicating function setting
Gch
Gch:
Outputs the Y/G/Y signal supplied to the CAMERA
connector from Y/G/Y connector. (At normal use)
AUX_Rx: In the SDI mode, outputs the RS-232C signal
supplied to the INTERCOM/TALLY/AUX connector
from CAMERA connector. (At AUX RS-232C
communicating function use)
$1001
RTS 200 OHM
Turns ON/OFF 200 Q termination when the external
OFF
INTERCOM_RTS system is used.
$2001
ROM WRITE SW
RCP:
At normal use
RCP
ROM WRITE: Select when the software upgrading is executed.
$2004-4
MAINTENANCE mode
Turns ON/OFF the software version display.
OFF
IF-879 Board
For the settings of S101 (System setting switch) and S102 (Intercom setting switches) on the IF-879
board, refer to the Operating Instructions of this unit.