2-2. VBS Video Level Adjustment
2-3. RGB Video Level Adjustment
Adjustment Procedures
2-3.
RGB
Video
Level Adjustment
1.
Measure the output signal level "A" of the video signal
Equipment : Waveform monitor
generator and write down it.
Video signal generator (10 step signal with
sync)
Distributor
Camera cable CCZ-A100 (100 m)
Signal input tool (2 pieces)
Coaxial cable (with BNC connectors, 3 m or
less)
(Waveform monitor)
Connection
2. Connect the unit and equipment as shown in the
CCU-DS0/DS50P rear panel
connection diagram and input the video signal to the
connector of the camera cable.
CAMERA
YIGN RYRIC
BYB
Video signal input pin No. (Signal input tool)
©
Signal side : pin 1/Camera cable
GND side:
pin 2/Camera cable
CAMERA
3. Test Point :
VBS OUTPUT 1 connector (on
R-Y/RIC connector
connector
Y/G/Y connector
the rear panel)
B-Y/B connector
Adjustment Point : @RV201/PR-270/270A board
Specifications :
B=Ait2%
Camera cable
CCZ-A100
Coaxial cable
(3 m or less)
Waveform
eax
monitor
75.Q
;
-
Signal input tool A (hold)
Video signal
Signal side : pin 1
(Waveform monitor)
generator
4
B
»>
5 O
Raa f
Vv
BES RSS
GND side : pin 2
25 2
Distributor
od
2836
Video signal input pin No/
Signal input tool B ~Camera cable
PR-270/270A BOARD (A SIDE)
CCU-D50/D50P SMVIE