Fluidwell D Series User Manual

Totalizer, signal input: 0 4-20 ma flowmeter signal, options: backlight
Hide thumbs Also See for D Series:
Table of Contents

Advertisement

Quick Links

User Manual
D011-A
TOTALIZER
Signal input:
(0)4-20 mA flowmeter signal
Options:
backlight
D-Series - Panel mounted indicators
More info: www.fluidwell.com/dseries

Advertisement

Table of Contents
loading

Summary of Contents for Fluidwell D Series

  • Page 1 User Manual D011-A TOTALIZER Signal input: (0)4-20 mA flowmeter signal Options: backlight D-Series - Panel mounted indicators More info: www.fluidwell.com/dseries...
  • Page 2: Table Of Contents

    User Manual D011-A TABLE OF CONTENTS ABOUT THIS MANUAL......................How to use this manual ....................Use of pictograms ......................Warranty and technical support ..................Model Reference ......................SAFETY ............................ Personal safety ....................... End-user responsibilities....................Potential equipment damage ..................Disposal of electronic waste ................... INTRODUCTION........................
  • Page 3 D011-A User Manual Battery replacement......................24 7.3.1 Safety instructions ......................24 7.3.2 Battery replacement procedure ..................24 7.3.3 Disposal of batteries ....................... 25 APPENDIX A - TECHNICAL SPECIFICATION ................26 General ........................... 26 Input ..........................27 Operational ........................27 APPENDIX B - TROUBLESHOOTING ................... 28 APPENDIX C - LEGAL INFORMATION ..................
  • Page 4: About This Manual

    ● incorrect functioning of the unit or connected instruments. A note informs you of important information. WARRANTY AND TECHNICAL SUPPORT For warranty and technical support on your Fluidwell products, visit our internet site www.fluidwell.com or contact us at support@fluidwell.com. MODEL REFERENCE Hardware version: 03.04.xx...
  • Page 5: Safety

    D011-A User Manual SAFETY PERSONAL SAFETY ● Risk of electric shock: Only open the unit if all leads are free of potential electrical energy. ● Immediately inform the person responsible for the installation if you disagree with the safety precautions or if you detect errors or danger. END-USER RESPONSIBILITIES ●...
  • Page 6: Introduction

    User Manual D011-A INTRODUCTION SYSTEM DESCRIPTION The totalizer model D011-A is a microprocessor-driven instrument designed to show a resettable total and a non-resettable accumulated total. Fig. 1: The D011 This manual describes the daily use, configuration and installation of the D011-A with analog (0)4-20mA input from a flowmeter, and its available options.
  • Page 7: Installation Example

    D011-A User Manual INSTALLATION EXAMPLE Following parts can be recognized in below installation example. Fig. 3: Installation example D011-A 1. Front cover 3. Label 5. Keys 7. Clamp 2. Display 4. Protective earth 6. Mounting panel 8. Back side cover connection FW_D011-A_M_v0501-01_EN Page 7...
  • Page 8: Operation

    User Manual D011-A OPERATION This unit may only be operated by authorized and trained personnel who have read and understood this manual, particularly Section 2: Safety [»5] INTRODUCTION This chapter describes the daily use and operation of the D011-A. For this, the D-Series is equipped with a control panel that provides the operator with various functions, information and operating modes.
  • Page 9: Backlight (Type Zb)

    D011-A User Manual Normally, the display is updated depending on the refresh rate selected in the configuration settings. By pressing any key, the display switches to refreshing the information 8 times per second. After 30 seconds of key inactivity, the display returns to the configured refresh rate. ACC.TOTAL Fig. 4: Example of display information during process...
  • Page 10: Configuration

    User Manual D011-A CONFIGURATION INTRODUCTION This chapter describes how technicians can use configuration settings to configure the D-Series for optimal functionality. Configuration of the D011-A can be done in SETUP mode, using the front keys. CONFIGURING USING SETUP MODE For an overview of Operating modes, see Section 4.1.1: Operating modes [»8] Changing settings may influence current operation In SETUP mode the unit remains fully operational.
  • Page 11: Changing Configuration Settings

    D011-A User Manual 5.2.3 CHANGING CONFIGURATION SETTINGS A menu item either contains a value (a number with optionally a decimal point and sign, e.g. -123.45) or a selection list (e.g. L – m - USGAL). After a menu item is selected in the SETUP menu, a new value can be programmed by performing the following steps.
  • Page 12: Setup Menu Overview

    User Manual D011-A SETUP MENU OVERVIEW TOTAL DEFAULT UNIT L - m3 - kg - lb - GAL - USGAL - bbl - no unit DECIMALS 0 - 3 0.0010 - 999,999 1600 SPAN DECIMALS SPAN 0 - 6 DISPLAY DEFAULT BACKLIGHT off - on...
  • Page 13: Menu 2: Display

    D011-A User Manual TOTAL UNIT Determines the measurement unit for total and accumulated total. The following units can be selected: L - m3 - kg - lb - GAL - USGAL - bbl - no unit Changing the measurement unit will have consequences for operator and setup values.
  • Page 14: Menu 4: Flowmeter

    User Manual D011-A 5.4.4 MENU 4: FLOWMETER FLOWMETER FORMULA The D011-A can process the analog (0)4-20mA signal in two ways: linear or as a root. Interpolation: the signal is processed in a linear way ● R = S x I Square root: the signal is processed applying a square root, f.i.
  • Page 15: Menu 5: Others

    D011-A User Manual FLOWMETER CALIBRATE LOW The unit is calibrated in factory using a very accurate current source. In case the flowmeter signal does not equal (0)4mA at flow rate zero, this function is needed to set the minimum input current at flow rate zero. The input loop powered version of the D011-A (Type PL) requires an input signal of at least 4 mA, not lower.
  • Page 16: Installation

    User Manual D011-A INSTALLATION ● Mounting, electrical installation, start-up and maintenance of this instrument may only be carried out by trained personnel authorized by the operator of the facility. Personnel must read and understand this Operating Manual before carrying out its instructions. ●...
  • Page 17: Handling The D011-A Enclosure

    D011-A User Manual HANDLING THE D011-A ENCLOSURE 6.2.1 IDENTIFICATION Identification label To identify your D011-A device, all enclosures have a weatherproof identification label placed at the backside of the product. Fig. 7: Example of D0-Series identification label Serial number and year of production The serial number can be reviewed on the identification label, the installation label, or in .
  • Page 18: Mounting The D-Series

    User Manual D011-A 6.3.2 MOUNTING THE D-SERIES The D-Series unit is mounted by placing it in an opening in a panel or cabinet (see Section 6.3.1: ) and securing it. To ensure proper IP or TYPE rating, the panel should Mechanical dimensions [»17] be rigid with a flat surface.
  • Page 19: Electrical Safety

    D011-A User Manual 6.4.1 ELECTRICAL SAFETY First consult the table with limiting environmental conditions and safety parameters in Section 6.1: Installation / environmental conditions [»16] General remarks ● Please note that the D011-A that came with a power module type PM will carry 110V-230V AC when installed.
  • Page 20: Field Wiring Connections

    User Manual D011-A 6.4.3 FIELD WIRING CONNECTIONS ● Do ground the aluminum / stainless steel enclosure properly with a PE wire as indicated to the Protective Earth terminal. It is the responsibility of the installer to install, connect and test the Protective Earth connections in accordance with the local and (inter)national Rules and Regulations.
  • Page 21: Terminal Connectors

    D011-A User Manual Jumper setting External sensor supply voltage 8.2 V DC 12 V DC 24 V DC TERMINAL CONNECTORS Type passive Take notice of all safety and precautionary measures indicated in Section 6.4: Electrical and review installation [»18] Section 6.4.3: Field wiring connections [»20] Section 6.4.4: Power before applying any field or power supply wiring.
  • Page 22: Terminals S1-S2 (S4): Flowmeter Input

    User Manual D011-A 6.5.2 TERMINALS S1-S2 (S4): FLOWMETER INPUT The D011-A requires a (0)4-20mA flowmeter signal which will be processed 4 times per second with 16 bit accuracy. The input is not isolated. The screen of the signal wire can be connected to the common ground terminal (see Field wiring connections).
  • Page 23: Maintenance

    D011-A User Manual MAINTENANCE GENERAL DIRECTIONS ● Mounting, electrical installation, start-up and maintenance of this instrument may only be carried out by trained personnel authorized by the operator of the facility. Personnel must read and understand this Operating Manual before carrying out its instructions. ●...
  • Page 24: Battery Replacement

    à plus de 100°C (212°F) ou exposer à l'eau. Primary Lithium Battery - Only replace with Fluidwell recommended battery pack! Pile primaire au lithium - Remplacer uniquement par une pile recommandé par Fluidwell! Fig. 16: Marking battery type PB: Safe area StdLiBAT-021 (SPB02) 7.3.2...
  • Page 25: Disposal Of Batteries

    D011-A User Manual 4. Place the back side cover back on the product and secure it with the four screws. 5. Check that the battery is installed properly by checking that the screen has come on. 6. Reconnect the unplugged field connectors. 7.
  • Page 26: Appendix A - Technical Specification

    User Manual D011-A APPENDIX A - TECHNICAL SPECIFICATION GENERAL DISPLAY Type High intensity reflective numeric and alphanumeric LCD, UV-resistant Digits 7 with height 17mm (0.67”) and 11 with height 8mm (0.31”). Various symbols and measuring units. Dimensions 90 x 40 mm (3.5” x 1.6”) Refresh rate User definable: fast - 1 sec - 3 sec - 15 sec - 30 sec - off Type ZB (option)
  • Page 27: Input

    D011-A User Manual INPUT FLOWMETER Signal type (0)4-20 mA, with signal calibration feature. Type PL min. 4 mA. Accuracy 16 bit. Error < 0.01 mA or ±0.05% FS. Low-level cut-off programmable. Span with variable decimal position. Update time Four times per second Voltage drop Max 1 V DC @ 20 mA.
  • Page 28: Appendix B - Troubleshooting

    User Manual D011-A APPENDIX B - TROUBLESHOOTING Table 1 lists and describes how to troubleshoot problems that can occur when installing or operating the D011-A. Table 2 lists internal alarm codes and conditions signaled by a blinking ALARM flag on the display ).
  • Page 29: Appendix C - Legal Information

    EU De cla tio n of Conformi Fluidwell 0 D ‒Series indicators he , February 2022 We, Fluidwell BV, declare under our s e ol respons ibility that the 0 D ‒Series indicators are de igne d and will operate conform the following applicable European...
  • Page 30 User Manual D011-A LIST OF CONFIGURATION SETTINGS SETTING DEFAULT DATE: DATE: TOTAL UNIT DECIMALS SPAN 1600 DECIMALS SPAN DISPLAY BACKLIGHT BACKLIGHT BRIGHTNESS POWER MANAGEMENT LCD UPDATE 1 sec BATTERY MODE operational FLOWMETER FORMULA interpolation FILTER 01 (off) CUT-OFF CALIBRATE LOW factory CALIBRATE HIGH factory...
  • Page 31 D011-A User Manual NOTES FW_D011-A_M_v0501-01_EN Page 31...
  • Page 32 Fluidwell bv P.O. Box 6 Voltaweg 23 Website: www.fluidwell.com 5460 AA Veghel 5466 AZ Veghel Find your nearest representative: www.fluidwell.com/representatives the Netherlands the Netherlands © Copyright 2024 - FW_D011-A_M_v0501-01_EN...