PE5 Meter Setup and Operation Instructions
b. Press and hold the
Manual / Reset button
until CAL stops blink-
ing.
c. When CAL starts to
blink again, the display
should show 1.00,
which indicates the new calibration is com-
plete.
If an error was made during meter recalibration,
repeat Steps a - c of the recalibration process to
recalibrate the meter again.
d. Press and hold the
Auto / Reset button to
advance to the Auto
Preset Amount Menu.
Auto Preset Amount (F
Specifies an amount displayed when you enter the Auto
Dispense Mode. Typically, you would enter the amount
you most frequently dispense.
F
. 26
IG
1. If the Auto Preset Amount screen is not already dis-
played, complete steps 1 - 5 of the Setup Menus
section, page 15.
2. AUTO blinks indicating you are in the Auto Preset
Amount Menu. The currently stored auto preset
amount is displayed. (This is the amount that is dis-
played when the Auto / Reset button is pressed dur-
ing normal operation.)
18
. 26)
IG
PTS
QTS
GAL
LITERS
AUTO
R-TOTAL
ti12082a
3. Do ONE of the following.
a. To enter a new auto pre-
set amount press and
hold the 10 button to
change the 10's digit,
the 1.0 button to change
the 1's digit,
and the 0.1 button to
change the first decimal
digit. You cannot enter
zero.
To reset the display to 0.00, press and hold the
Manual/Reset button.
b. Press and hold the Auto /
Reset button to lock in the
amount. The Shut-Off
Default Amount Menu dis-
plays.
OR
Press and hold the Auto /
Reset button to lock in the
currently displayed auto
preset amount. The dis-
play advances to the
Shut–Off Default Amount
Menu.
312668B