Graco ME5 Instructions Manual page 10

Electronic metered dispense valves
Table of Contents

Advertisement

ME5 Meter Setup and Operation Instructions
Calibration (F
. 12)
IG
Recalibrates the meter for dispensing different fluids.
CAL
F
. 12
IG
1. If the Calibration Menu is not already displayed,
complete steps 1 - 4 of the Setup Menus section,
page 8.
2. CAL blinks indicating you are on the Calibration
Menu screen. Do ONE of the following.
Use the current calibration.
Press and hold Reset but-
ton to lock in amount. Dis-
play returns to the
Standard Mode.
OR
Recalibrate meter as follows:
a. If the unit of measurement is gallons, pints,
or quarts, dispense exactly one quart of fluid
into a calibrated 1–quart container.
If the unit of measurement is liters, dispense
exactly one liter of fluid into a calibrated
1–liter container.
For proper calibration, you must dis-
pense the exact amount.
10
PTS
QTS
GAL
LITERS
R-TOTAL
ti12046a
b. Press and hold Total
button until CAL stops
blinking.
c. When CAL starts to
blink again, the display
should show 1.00. The
new calibration is com-
plete.
If an error was made during meter recalibration,
repeat Steps a - c of the recalibration process to
recalibrate the meter again.
3. Press and hold the Reset but-
ton. The unit returns to Stan-
dard Dispense Mode.
312668B