Even though others may install your vessel, you should make few installation checks before
system start-up. Vessels must be installed correctly to ensure safe use and long service life.
Check that vessels are mounted on horizontal support frame using compatible black
urethane saddles with hold-down straps that are snug & not tight.
Check that each vessel is free to expand under pressure, shell is not rigidly
clamped in place, and piping to vessel is not connected using rigid connections.
Check that vessel does not support any other component; that piping manifolds
are separately mounted, and that interconnection piping is self supported and
connected to the pressure vessel with IPS grooved couplings.
If you have any question about the installation of vessel in your unit, contact your supplier.
For installation guidelines, refer to page no. 30-32.
Models
Max. Operating
Pressure (PSI)
Operating Temp.
Range (degree F)
Factory Test Pressure
(PSI) ASME (1.1X)
Factory Test Pressure
(PSI) CE/PED (1.5X)
Prototype Min.
Qualification Pressure
(PSI)
Operating pH Range
Cleaning pH Range
Engineering Drawing
No.
(Coded)

INSTALLATION NOTES

WARNING
FAILURE TO ALLOW EXPANSION
IN DIAMETER OR LENGTH WILL
RESULT IN VESSEL DAMAGE.
80E30
80E45
300
450
330
495
450
675
1800
2700
99111
99112
80E60
80E100
600
1000
20 – 120
660
1100
900
1500
3600
6000
3 - 11
2 - 12
99109
99108
80E120
1200
1320
1800
7200
99110
Page 7 of 38

Advertisement

Table of Contents
loading

Table of Contents