Claims & Notes - Pentair Everpure H-300 Installation Instructions Manual

Quick-change filter cartridge
Hide thumbs Also See for Everpure H-300:
Table of Contents

Advertisement

Available languages

Available languages

2. VERIFY UNDER-SINK MOUNTING LOCATION
Measure 22" from the base of the cabinet, and mark the
mounting location for the top of the filter head. Measure
13" for the width required for the H-1200 System with
dual cartridges. Make sure there is adequate space above
the head to open and close the shut-off valve and to avoid
crimping the water line tubing. Also, make sure your
chosen location offers easy access for future cartridge
changes.
DIMENSION
Width
H-1200
13"
NOTE: The head and cartridge must be mounted in the
vertical position, with the cartridge hanging down.
3. MOUNT FILTER HEAD UNDER SINK
A. Identify Dual Filter Head and Shut Off Valve (EV309860).
B. Apply Plumbers Tape to the threads on the inlet (left)
side of the Head. Screw on the new Shut Off Valve
and hand tighten. Repeat for the Stainless Coupler
(EV312350) for the outlet (right) side of the Head.
C. Apply Plumbers Tape to the threads of the Outlet
Elbow Fitting (black band). Screw into the outlet of
the Stainless Coupler. Wrap tape in direction of the
threads to assure a tight fit and avoid small leaks.
D. Securely mount the filter head on the cabinet wall
using the enclosed mounting screws and washers.
4. Go to page 5 and follow Basic Installation Instructions,
Steps 4, 5, and 6, to complete the H-1200 System
installation.
CLAIMS & NOTES
This installation must comply with all applicable state and
local regulations.
Do no use with water that is microbiologically unsafe or
unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may
be used on waters that may contain filterable cysts.
Testing was performed under standard laboratory
conditions, actual performance may vary.
EPA Est. No. 002623-IL-002
H-54, H-300, H-104, H-300-HSD & H-1200 Systems
Tested and Certified by NSF International against NSF/
ANSI Standards 42 and 53 of claims specified on the
Performance Data Sheet.
This H-300-NXT System Tested and Certified by NSF
International against NSF/ANSI Standard 42, 53 and
401 of claims specified on the Performance Data
Sheet.
NSF/ANSI Standard 401 have been deemed as
"incidental contaminants/emerging compounds".
Incidental contaminants are those compounds that have
been detected in drinking water supplies at trace levels.
While occurring at only trace levels, these compounds
can affect the public acceptance/perception of drinking
water quality.
Height
Depth
22"
5"
2
Dual Filter Head
3
B
EVERPURE
22"
Shut Off Valve
A
C
D
H-Series Water Filtration Systems
• 7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Everpure h seriesEv927072

Table of Contents