Over pressure protection
It is essential that over pressure protection be provided such that the pressure to which any
vessel is subjected cannot exceed 105% of design pressure.
Mounting
The pressure vessel should not be used as a support. Piping manifolds and other fittings should
be supported by properly designed system framework. Operating personnel should be
discouraged from applying from undue force to any fittings connected directly to a pressure
vessel.
Accessibility
Pressure vessel should be positioned within the system such that elements can be inserted at
the upstream end and removed from the downstream end (i.e. elements are installed and
removed in the direction of feed flow).
AFTER END OF SERVICE LIFE OF VESSEL, DISPOSE THE VESSEL AND ITS
COMPONENTS AS PER APPLICABLE LOCAL LAWS AND REGULATIONS
FOR
LATEST
https://codeline.pentair.com/en/downloads
Warranty FRP Housings
SAFETY
SECTION 4 - APPENDIX
WARRANTY TERMS & CONDITION