C. Removing head assembly using tool (Part # TO-10273)
Step 1:
The Head removal tool (P/N: TO-10273) consists of three parts (applicable to 8"
models only). a.) Base Plate c) Stud Threaded (2 no's) d) T-Socket (2 no's)
Step 2:
Engage the stud in the threaded holes provided on the bearing plate.
Step 3:
With the plate against the face of the vessel, engage the T-Socket with the threaded
studs.
Step 4:
Run the hand grip on the T-Socket's and continue to tighten (clock-wise) till the head
assembly comes out.
Read all guidelines in this section before attempting to open the vessel.
Do not attempt to service any component without first verifying that vessel PRESSURE is
fully relieved from the vessel. Attempting to remove any component before pressure is
relieved may result in EXPLOSIVE release of the head.
OPENING THE VESSEL
WARNING
Page 12 of 38