[GPS Position] section
Menu item
[Longitudinal (from
bow]
[Lateral (-Port)]
[Data Damping] section
Menu item
[COG & SOG]
[Heading]
[Speed Through Water]
[Wind Speed &Angle]
[Rate of Turn]
[IF-NMEAFI Setup] section
Menu item
[Select IF]
Select [IF-NMEAFI] to set the analog data that is input from the IF-NMEAFI.
The setting is made after restarting the IF-NMEAFI.
[Category]
Select the use (category) for this sensor.
[Resistance Full]
The resistance, in Ohms, when the tank is full. [0] (ohm) to [500] (ohm)
[Resistance Mid]
The resistance, in Ohms, when the tank is half
full.
[Resistance Empty]
The resistance, in Ohms, when the tank is
empty.
[Capacity]
The capacity of the tank.
[Fluid Instance]
Select the NMEA instance for the tank.
[Self test]
Test results are displayed.
[Set Hardware to
Resets the converter selected at
Factory Default]
[Select IF] to factory default.
[Fusion] section
Menu item
[Connect to Fusion]
[Fusion Auto Volume]
[Minimum Speed]
[Maximum Speed]
[Volume Increase]
[Service / Self Test / Log] section
Menu item
[Synchronization Log]
Description
Referring to the figure on the
right, enter the GPS antenna
positioning bow-stern
(Longitudinal) and
port-starboard (Lateral)
position from the origin.
Description
Set data damping time. The lower the setting
the faster the response to change.
Description
Description
Connects to your Fusion equipment.
Set to [ON] to allow the TZT22X/24X unit to
control the FUSION volume automatically.
Set the minimum speed threshold. Exceed-
ing this speed activates volume auto control.
Set the maximum speed threshold.
Set the amount of extra volume to output .
Description
Shows synchronization with devices connected to the network.
3. HOW TO SET UP THE EQUIPMENT
Options (setting range)
0 (m) to 999 (m)
-99 (m) to +99 (m)
Origin
Origin
Port-side is negative,
Starboard-side is positive.
Options (setting range)
0 to 59 seconds
Options (setting range)
[Wind], [ST800_850], [Fuel],
[FreshWater], [WasteWater],
[LiveWell], [Oil], [BlackWater]
[0] (ohm) to [500] (ohm)
[0] (ohm) to [500] (ohm)
[0] (G) to [2650] (G)
[000] to [254]
[OK], [Cancel]
Options (setting range)
[ON], [OFF]
0.0 (kn) to 98.9 (kn)
0.1 (kn) to 99.0 (kn)
10% to 50%
Options (setting range)
3-7