Set Low Battery Indicator; Set Media Sensitivity - Honeywell RP2F Series User Manual

Ez-print command reference
Table of Contents

Advertisement

Set Low Battery Indicator

Sets the voltage at which the low battery indicator turns on.
Command
ESC{SSC:V:x.x}
where:
x.x sets the level at which the low battery indicator turns on. Range is 0 to 8.4 V.
Example
This command sets the low battery indicator on the printer to 7.2 V
ESC{SSC:V:7.2}
Returns this reply if the command is not successful:
{SSC:V:1}
Returns this reply if the command is successful:
{SSC:V:0}

Set Media Sensitivity

Sets the sensitivity for the media you are using. Intermec recommends that you use the default
setting for media sensitivity.
Command
ESC{SSC:M:F1,F2}
where:
F1: The printhead Manufacturer ID. The printer supports K, S, and R.
F2: Sets the media sensitivity of the printhead:
0: Direct Thermal (default)
l
1: Thermal Transfer
l
Example
This command sets the media sensitivity to Thermal Transfer.
ESC{SSC:M:S,1}
Returns this reply if the command is not successful:
{SSC:M:1}
Returns this reply if the command is successful:
EZ-Print Command Reference
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rp4f series

Table of Contents