Enelion LUMINA User Manual

Enelion LUMINA User Manual

Premium charger for electric vehicles
Hide thumbs Also See for LUMINA:
Table of Contents

Advertisement

Quick Links

User
manual
ENELION
Premium charger for electric vehicles
LUMINA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LUMINA and is the answer not in the manual?

Questions and answers

Summary of Contents for Enelion LUMINA

  • Page 1 User manual ENELION LUMINA Premium charger for electric vehicles...
  • Page 2 Dear user Congratulations on your purchase of the Enelion charger and thank you for your trust. Up-to-date manuals for users and installers always available at: https://enelion.com/support-lumina/ Please read this manual before installation or prior to the station being commisioned.
  • Page 3: Table Of Contents

    Safety instructions Use of the charging station Preparation for use Completion of charging Emergency stop Procedure in the event of irregularities, faults and fire General rules for safe operation Health and Safety Disposal and environmental protection Device configuration Available variants Initiating the device Changing the configuration LED bar...
  • Page 4 OCPP Connection Mains Authorization Accessories Modbus Charging network Overview DLB Overview System Overview Update Users Time Technical data Reboot Cleaning Operation Operation and maintenance of charging stations Technical tests Measurement of the resistance of the Main Earthing Terminal– MET grounding Continuity measurement of the protective conductors Testing insulation resistance Measurement of resistance of the working grounding...
  • Page 5 PP contact - detection of the plug and charging cable. CP contact - communication line between the vehicle and the charging station. Servicing the charging station Instructions for replacing the 230 V socket fuse in ENELION LUMINA Technical description Troubleshooting...
  • Page 6: Safety Instructions

    The electrical installation to be used during device operation must comply with the legal standards applicable at the installation and operation The Enelion charger (hereinafter referred to as location of the device. the device, charger, or charging terminal) is a...
  • Page 7 (extended warranty/service) subject to a qualifying review before purchasing the package. Details can be obtained from the Enelion sales department. The charging station does not support ventilation functions. The nameplate present on the device is an...
  • Page 8: Use Of The Charging Station

    Use of the Preparation for charging Before the first use of the charger, make sure station that the charger has been correctly installed and poses no danger to the user. More information may be found in the installation quide. Charging By default the charger is configured as Free Charge configuration, which means it starts charging as soon as a car is connected.
  • Page 9: Completion Of Charging

    fact with the light bar and showing the status on Emergency stop the display. While charging, the light bar flashes from the center towards the edge. See chapter LED interface for more information. When configuring the station as Free Charge, it is possible to disable the locking of the plug in The charging process can be interrupted by the station before charging.
  • Page 10: General Rules For Safe Operation

    General rules for safe operation The device meets the IP 54 standard. Due to the IP 54 class of the device, it is forbidden to wash the charger with pressure washers, garden hoses, a shower or any other The device should be used in accordance with the stream of water.
  • Page 11: Disposal And Environmental Protection

    Disposal and environmental protection Electrical and electronic waste must not be disposed of together with normal household waste. According to the WEEE directive in force in the EU, separate methods of disposal must be used for electrical and electronic waste. In accordance with the provisions on waste electrical and electronic equipment, it is forbidden to put waste equipment (marked with...
  • Page 12: Device Configuration

    Device Available variants configuration The system of configuring the settings of ENELION LUMINA charger is done in the configuration panel. Available variants resulting from the configuration of the device are presented below: ► Type of power system • One–phase power system — only the first phase connected to the device will be used for charging.
  • Page 13: Initiating The Device

    To configure the charger you need to: 1. install the charger according to the fitting instruction available on https://enelion. com/support-lumina/, 2. turn power supply on, 3. connect with secured AP of the station, 4. log in to the configuration panel on the...
  • Page 14: Led Bar

    Green flashing Charging (energy transfer Blue flashing from inside in progress) towards the edge Charging (no energy Blue flashing The ENELION LUMINA charging transfer) station has an LED interface that provides the user with basic Warning/minor error Yellow flashing information:...
  • Page 15: Configuration Panel

    • Management of access to the charging point • Remote diagnostics and software update. Communication ENELION LUMINA charger allows you to connect to the configuration panel using its Wi-Fi Hotspot. In order to connect to the Wi-Fi Hotspot, use a computer or your smartphone to scan the...
  • Page 16: Access To The Configuration Panel

    Wi-Fi networks. The broadcast network There are accounts for the User (User) and is named Enelion-XXXX-XXXX where X signs Administrator (Admin) in the configuration stand for the charger’s serial number. Password panel. The default password for each of these...
  • Page 17: Navigation In The Configuration Panel

    The Dashboard tab contains basic information about the overall status of the ENELION LUMINA and the charging network and presents them in the form of tiles. Depending on the situation, not all tiles will be visible. The available tiles are:...
  • Page 18: Wi-Fi

    Available Wi-Fi networks section presents connection will automatically turn off. To re- a list of Wi-Fi networks detected by the ENELION enable Wi-Fi, you must first disable Ethernet. LUMINA in its vicinity, along with information Otherwise, a message will appear as shown in the about the signal level and Type of security.
  • Page 19: Gsm

    05.4 ENELION LUMINA is equipped with LTE cat 4 module. To connect the module with GSM internet please, before powering the charging station on, make sure that the SIM card is properly inserted in the SIM slot. GSM configuration window.
  • Page 20: Ocpp

    Tag ist the tag used to OCPP authorization when Free Charge mode is enabled and RFID tag is not used. ENELION LUMINA supports OCPP 1.6 over JSON. To connect to OCPP backend please use the toggle on the right of OCPP Connection header.
  • Page 21 for editing the value of a given configuration key. For read-only keys it is not possible to change their value. Changing the value of these keys can change the behavior of the charging stations undesirably. Only use this feature if you know what you are doing.
  • Page 22: Mains

    In the Mains section, we can check Mains status Enelion charging stations are featured with a and settings like power limit or phase sequence. Dynamic Load Balancing (DLB) function. It allows all the charging stations in the network to share...
  • Page 23: Authorization

    Charging Network section has been activated in the configuration panel and that the Lumina charger is communicating with at least Authorization section in the Charger tab. one other station. Failure to perform these...
  • Page 24: Accessories

    Possible lock modes are explained in the table The 230 V relay socket can be turned on or off, and you can also set a delay for the socket’s below: shutdown to a specified time. If an RCM B module is installed in the charger, it Lock state Description can be enabled using the switch on the right side.
  • Page 25: Modbus

    The load on the 230 V socket is not included in the DLB charger load. The 230 V socket can be considered as an external load when the Enelion Energy Guard is installed in the network to which the charger is connected. 07 .7...
  • Page 26: Charging Network

    DLB non-functional, it will switch to low-power mode and charge the Charging network section allows for car with 6 A current. managing the network of Enelion devices connected locally to exchange charging, ocpp and maintenance related data. 08.1 Overview...
  • Page 27 In the charging network settings, you can choose click on the Edit icon and enter the preferred the type of connection for ENELION LUMINA values in the fields. Finally, click Save and wait chargers in the network. You can choose between for the devices to connect to each other.
  • Page 28: System

    ENELION LUMINA head and Backplate hardware details. After file upload and verification the ENELION LUMINA will present a window with update details to confirm the choice. An example of update details ENELION LUMINA will start an update. The Overview section of the System tab.
  • Page 29: Time

    OCPP and Update. Other functions to which the user has limited rights are: viewing logs and changing the administrator password. The list of events that occurred in the ENELION LUMINA is available on the Logs subpage. Depending on whether we are interested in logs...
  • Page 30: Technical Data

    09.6 Reboot The Reboot button allows you to restart the ENELION LUMINA. After two minutes, the configuration panel will display the Dashboard section. Reboot section of the System tab. Technical data Technical data Wi-Fi 2.4 GHz, 802.11 bgn GSM modem LTE Cat 4, Max.
  • Page 31: Cleaning

    The device is designed to operate in temperatures Maintenance from −30 C to +55 C. The manufacturer does not guarantee the proper functioning of the charging station in temperatures outside the specified range. Chargers that are damaged because of exposure to temperatures below −30 C or above 55 C are not covered under the warranty.
  • Page 32: Operation

    Operation and Operation maintenance of charging stations The inspection is not obligatory. Mechanical elements such as the socket, charging cable, plug lock, plug, plug holder, and other fixed components only require a superficial examination. They are not expected to wear out or need replacement during the operational period of the station.
  • Page 33: Measurement Of The Resistance Of The Main Earthing Terminal-Met Grounding

    Continuity 02.1 02.2 Measurement of measurement of the resistance of the protective the Main Earthing conductors Terminal–MET grounding The measurement should be made between the main potential equalization point and PE contact The Main Earthing Terminal in the station is the PE (wire input on the backplate) in the charging contact in the power connector.
  • Page 34: Testing Insulation Resistance

    02.3 Measurement of resistance When measuring the insulation resistance, of the working the supply voltage absolutely must be disconnected without any possibility of it grounding being accidentally reconnected! Perform the measurement if the working grounding has been made. The measurement If overvoltage protectors have been used in can be made by technical, compensatory, clamp the tested installation, the connection of the...
  • Page 35: Testing Resistance Of The Charging Station Insulation

    Testing resistance of measured resistance value, should not be used for insulation measurements. It is permissible the charging station to use adapters that do not contain additional 03.2 insulation circuits, being adapters for the measurement system. Otherwise, the measurement should be carried out directly on the contacts of the socket/ plug of the station, observing appropriate safety Additionally, an insulation resistance measurement...
  • Page 36: Protection Against Electric Shock In Tt Systems

    current at the measurement site will be sufficient to trip the overcurrent protection at the required time. To assess the effectiveness of protection, take the most favorable result. The following condition must be met: Zs Ia ≤ U0 for t ≤ 0, 4s Zs –...
  • Page 37: Testing The Operation Of Residual Current Devices

    • Connect the RCD testing meter to the adapter 61851-1: 2019-10 standard). (vehicle simulator), • Start the charging process using the adapter - Each ENELION LUMINA station includes an the LEDs should be blue, Enelion RCM B accessory: • Follow the instructions on the meter while measuring the RCD breaker parameters, •...
  • Page 38: Rcm B Tests

    Normalized, maximum switch-off times [s] for the Measurement of the actual sensitivity of RCM B: RCD B differential current: RCM B = 0,5IΔn ≤ IΔr ≤ 2IΔn, 2I Δn 4I Δn 10 Δn I Δn ≥5A Where: IΔn = 6mA – nominal sensitivity of the 0,15 0,04 0,04...
  • Page 39: Functional Tests

    Functional THE RESISTANCE THE RATED CURRENT VALUE OF RC (±3%) CAPACITY OF THE tests CABLE Functional tests must be carried out with a 220 Ω 32 A suitable tester. 680 Ω 20 A Functional tests should be carried out at least 1500 Ω...
  • Page 40: Servicing The Charging Station

    Charging in progress The main component of the ENELION LUMINA - Status LED: Blue, pulsating from the charging station – the head unit – is not subject center towards the to service repairs. Fault rectification involves edges replacing the head unit.
  • Page 41: Lumina

    RCM B 6 mA DC in ENELION LUMINA 5x6 mm C 1000 V Applies to ENELION LUMINA charging stations equipped with an additional 230V socket Additional 230 V socket allows you to connect a load of no more than 10A.
  • Page 42 Fuse: 0234010.MXP (Cartridge Fuse 250 V 10 A Medium Acting) The fuse is located in the housing on the cable in the backplate part of the charger. 1. Unscrew the fuse housing. 2. Remove the blown fuse from the housing 3.
  • Page 43: Technical Description

    Technical description...
  • Page 44 IK10 Impact protection UL94-V0 Flammability class ENELION LUMINA ALU CABLE – Type 2 connector with 5.2 m cord Charging connector type ENELION LUMINA ALU SOCKET – Type 2 socket ENELION LUMINA SOCKET – Type 2 socket Embedded residual current monitor – Enelion RCM B 6 mA DC Residual current protection Integrated 3-phase energy meter >99% accuracy...
  • Page 45 3 x 400 V AC/ 230 V AC (±10 %) (TN/IT) Supply voltage Possibility of connecting the cable from the top, bottom and the back of the station configuration with no additional tools remotely controlled 230 V outlet (max. 2000W/10A)* Other features remote start / stop, delay and charging schedule temperature and humidity monitoring inside device...
  • Page 46: Troubleshooting

    Frequently Asked Questions ENELION LUMINA CHARGER DOESN’T CONNECT TO THE Wi-Fi NETWORK Make sure the Wi-Fi password was entered correctly and that the proper security method was chosen Authentication Type box. Positioning the Wi-Fi router closer to...
  • Page 47 Customer service ENELION LUMINA CHARGER DOESN’T Download the latest user manuals, useful CONNECT TO THE GSM NETWORK documents and videos for your product on enelion.com Make sure the GSM network settings were entered correctly and that the charger is in the network signal range.
  • Page 48 Copyright, Enelion sp. z o. o. The manual may change as the product develops. All rights reserved. Revision: V 8.2 Number of pages: 48 Released: April 18, 2024 Enelion sp. z o.o. | Miałki Szlak 52 80–717 | Gdańsk | Poland sales@enelion.com enelion.com...

Table of Contents