  • Page 1 ENELION VERTICA Manual for ENELION VERTICA Modules, ENELION VERTICA Pole and accessories. Enelion sp. z o.o. support@enelion.com...
  • Page 2 Congratulations on the purchase of the Enelion charger and thank you for your trust. Before the installation, make sure that the module packages contain all the elements. Current version of the operation manual can be accessed at: https://enelion.com/en/support/ See the contents of the manual before initiating any activities related to the installation or the activation of the charger.
  • Page 3: Table Of Contents

    5. Installation of ENELION VERTICA Pole 5.1. Preparation for installation 5.1.1. Standard connection 5.1.2. Enelion MID Add-on 5.2. Internet connection via Ethernet interface in the LAN 5.3. Enelion Chain 5.3.1. Add-on – ENELION VERTICA Splitter with an additional meter and residual current protec-...
  • Page 4 5.4. Installation of ENELION VERTICA bottom masking panels 6. Installation of the ENELION VERTICA Module 6.1. Preparation for installation of the ENELION VERTICA Module with socket 6.2. Preparation for installation of the ENELION VERTICA Module with a cable 6.3. Installation of accessories 6.3.1. Enelion Bridge 6.3.2.
  • Page 5: Important Information

    It is prohibited to power on the device when the 1.1. General Provisions device housing is open. The Enelion charger (hereinafter referred to as the It is prohibited to use a charger that is mechanically device, charger, or charging terminal) is a charging damaged or indicates a critical error.
  • Page 6: Safety Instructions

    Vertica - assembly manual 10 - 2023 1.2. Safety instructions Do not carry out external installation during atmo- spheric precipitation or strong winds if there is a risk of water or contaminants entering the device. All actions described in this manual should be per- formed after ensuring that there is no voltage in the power cable.
  • Page 7: General Information

    For more information, please refer to the User electric cars, Manual. It contains detailed information about which consists of ENELION VERTICA Pole as a casing, the functionality and use of the device. ENELION VERTICA Modules involved in the charging process and optional addons and accessories.
  • Page 8 Vertica - assembly manual 10 - 2023 INFO In order to close the ENELION VERTICA Pillar, perform all steps in reverse order. INFO Closing and opening of the ENELION VERTICA Pole does not change depending on the presence of ENELION VERTICA Modules in the device.
  • Page 9: Enelion Vertica Module

    ENELION VERTICA Module with a cable 2.3.1. ENELION VERTICA Module with a The ENELION VERTICA Module with a cable is a func- socket tional part of the charging station. The ENELION VERTICA Module with a socket is a functional part of the charging station.
  • Page 10: Assembly And Disassembly Of Enelion Vertica Modules

    To shut down the device, perform all steps in reverse order. WARRING ENELION VERTICA modules equipped with ENELION VERTICA link are only compatible with ENELION VERTICA poles that are equipped with ENELION VERTICA link modules! ENELION VERTICA modules equipped with...
  • Page 11 Assembly of ENELION VERTICA Modules Close the ENELION VERTICA Pole in accordance with the instruction 2.2.1 Opening and closing of the device. Fig. 12: ENELION VERTICA module compatible with a pole equipped with a ENELION VERTICA link module General information...
  • Page 12: Design Indications Of The Installation

    N and PE, as shown in the diagram below. 3.1. Electrical Connection Recommendation Enelion charging stations are adapted for five-wire power supply. In a TN-S 230/400V network, this is the standard option. It is possible to power the station from other network...
  • Page 13: Recommended Electrical Connection

    RCD B purchased from Enelion together with the device. It is also possible to use the Enelion RCM B – Residual Current Monitor type B accessory – see section 6.3.2 Enelion RCM B. Enelion RCM B additionally protects the station and, together with the RCD A used in the switchgear, meets all safety requirements.
  • Page 14: Location Selection Criteria

    Vertica - assembly manual 10 - 2023 of the ENELION VERTICA Pole is typically made with the space above the outline of the device. This space two separate 5 x 6 mm Due to the modular structure is required for servicing the charging station.
  • Page 15: Connection Type Diagrams

    Vertica - assembly manual 10 - 2023 3.4.1. Connection type diagrams Fig. 14: Connection types part 1/2 Design indications of the installation...
  • Page 16 Vertica - assembly manual 10 - 2023 Fig. 15: Connection types part 2/2. Design indications of the installation...
  • Page 17: Pictorial Diagrams Of Enelion Vertica Modules

    Vertica - assembly manual 10 - 2023 3.4.2. Pictorial diagrams of ENELION VERTICA Modules Fig. 16: Pictorial diagrams of ENELION VERTICA Modules part 1/2. Design indications of the installation...
  • Page 18 Vertica - assembly manual 10 - 2023 Fig. 17: Pictorial diagrams of ENELION VERTICA Modules part 2/2. Design indications of the installation...
  • Page 19: Foundation

    An excavation of over 400 mm x 600 mm (diam- eter x depth) or 400 mm x 400 mm x 600 mm ENELION VERTICA Pole can be installed in three ways: (width x length x depth) should be made. Com- pact the soil directly under the foundation to the •...
  • Page 20: Appropriate Existing Foundation

    In case there is an existing foundation suitable for the purpose, equipped with an electrical connection, meeting the legal and construction requirements, it is possible to install ENELION VERTICA Pole after ensuring that ENELION VERTICA Pole is properly Fig. 23: Properly constructed foundation with the attached to the foundation.
  • Page 21: Enelion Foundation Set

    ENELION VERTICA Pole. To construct the foundation of250 mm x 600 mm (diameter x depth) or 250 correctly, the Enelion foundation set needs to be set mm x 250 mm x 600 mm (width x length x depth). in concrete in the excavation.
  • Page 22 Cross-section of the foundation set cast in the concrete plate. The washers and nuts will be needed later to affix ENELION VERTICA Pole. Secure the bolts partly protruding from the con- Fig. 27: Details of placing the upper base plate in...
  • Page 23 Screwing nuts and spacer washers onto Fig. 30: Correctly cast foundation set. protruding rods. Fig. 31: Removing of the upper base plate from the foundation set. The foundation prepared in accordance with the above instructions is ready for ENELION VERTICA Pole to be mounted. Foundation...
  • Page 24: Installation Of Enelion Vertica Pole

    • Torx Security T25 bit. ENELION VERTICA Pole is mounted to the ground with Open ENELION VERTICA Pole as instructed in 4 M12 nuts screwed onto the previously prepared section 2.2.1 Opening and closing of the device threaded rods.
  • Page 25 Vertica - assembly manual 10 - 2023 Fig. 34: Mounting ENELION VERTICA Pole on the foundation. Fig. 36: Mounted and bolted ENELION VERTICA Pole. Fig. 35: Cross-section through the base of the ENELION VERTICA Pole during assembly. Installation of ENELION VERTICA Pole...
  • Page 26: Standard Connection

    ENELION VERTICA Pole! HINT The colors of the wires in ENELION VERTICA Pole may not match the colors of the power cables maintaining, however, the guidelines on the ENE- LION VERTICA Module label.
  • Page 27 Fig. 40: MID meter fitted in ENELION VERTICA Pole. Pole. Mount Enelion MID on the free DIN3 rail and con- In the case of a ENELION VERTICA pole equipped nect the phase conductors and the neutral one with a ENELION VERTICAN Module, connect two...
  • Page 28 MID meter. on the packaging label of the ENELION VERTI- CA Module, intended for this socket of ENELION VERTICA Pole, which should be interpreted in ac- cordance with the attached diagram. An example connection is as follows.
  • Page 29: Internet Connection Via Ethernet Interface In The Lan

    Insert the Ethernet patch cord into the device HINT through the gland for communication cables. In case of two MID meters in the ENELION VER- End the cable with the RJ45 connector according TICA pole, the second one should be connected to the TIA-568A/B do 100BaseT.
  • Page 30: Enelion Chain

    HINT In case of two MID meters in the ENELION VER- TICA pole, the second one should be connected correspondingly, to the other two pins. HINT...
  • Page 31 Chain network can be made in various ways. Prepare Communication Cables • In the case of an ENELION VERTICA pole equipped with an ENELION VERTICAN Module, secure the wires in the plug using the screw connector (ele- vator) according to the markings on the ENELION Fig.
  • Page 32 Vertica - assembly manual 10 - 2023 Installation of ENELION VERTICA Pole...
  • Page 33 (see Fig. 56) on the pins in accordance with the attached diagram (see Fig. 57). • In the case of the ENELION VERTICA Link vari- ant (see Fig. 59), termination is done by sliding the switch to the left, to the “ON” position.
  • Page 34: Add-On - Enelion Vertica Splitter With An Additional Meter And Residual Current Protec

    If power is supplied to the charging station using a single cable, it is necessary to use a safe Enelion-pro- vided branching. It includes a connection terminal, over current protection, and residual current protection.
  • Page 35 Vertica - assembly manual 10 - 2023 Fig. 61: Obverse of the ENELION VERTICA Pole after Fig. 62: Reverse of the ENELION VERTICA Pole after mounting the ENELION VERTICA Splitter with the mounting the ENELION VERTICA Splitter with the MID meter present.
  • Page 36: Installation Of Enelion Vertica Bottom Masking Panels

    5.4. Installation of ENELION VERTICA bot- tom masking panels ENELION VERTICA bottom filler panels cover the lower part of ENELION VERTICA Pole, while providing the ability to read the optional Enelion MID meters. The bottom filler panels should be raised above the...
  • Page 37: Installation Of The Enelion Vertica Module

    6.2. Preparation for installation of the ENELION VERTICA Module with a cable TICA Module The ENELION VERTICA module with a cable is delivered individually in a package. INFO If you are building an advanced charging station Place the packed ENELION VERTICA Module with...
  • Page 38: Installation Of Accessories

    The label on the ENELION VERTICA Module ing down. In the case of the ENELION VERTICA packaging provides key information regarding Module with a cable, the fact of the device having electrical connection.
  • Page 39: Enelion Rcm B

    TICA Module will not respond to its presence. Place the equipped ENELION VERTICA Module on a stable and flat surface with the front fac- ing down. In the case of the ENELION VERTICA Fig. 66: Enelion Bridge attached to the ENELION Module with a cable, the fact of the device having VERTICA Module.
  • Page 40: Enelion Lte Module

    6.3.3. Enelion LTE Module HINT Enelion LTE module is mounted in the same module The direction of cables going through the RCM B as Enelion Bridge. As with the Bridge module, thanks hole does not matter. The RCM B monitor can be...
  • Page 41 Vertica - assembly manual 10 - 2023 Place the equipped Vertica Module on a stable Connect the antenna cable. Guide the antenna and flat surface with the front facing down. Next, cable through the dedicated hole and screw the remove the rear cover of the Vertica Module.
  • Page 42 Vertica - assembly manual 10 - 2023 Fig. 76: Properly mounted LTE module. Installation of the ENELION VERTICA Module...
  • Page 43: Activation And Use

    ENELION VERTICA Pole. the proper functioning of the charging station in tem- peratures outside the specified range. Chargers that Open the ENELION VERTICA Pole (if closed after are damaged because of exposure to temperatures installation) according to section 2.2.1 Opening below -25 C or above 55 C are not covered under the warranty.
  • Page 44: Technical Data

    Vertica - assembly manual 10 - 2023 8. Technical data 8.1. ENELION VERTICA Pole Electrical data Routing of the power cord Sub-surface Recommended minimum cross-section Power cord cross-section • 5 x 6,0 mm2 (32 A nominal current) Supply voltage (Europe)
  • Page 45: Enelion Vertica Module With A Socket

    Vertica - assembly manual 10 - 2023 8.2. ENELION VERTICA Module with a socket Electrical data Supply voltage (Europe) 3 x 230 V / 400 VAC (+-10%) Voltage frequency 50 Hz / 60 Hz TN, TT Network type (IT per request) Overvoltage category III according to EN 60664–1...
  • Page 46: Enelion Vertica Module With A Cable

    Vertica - assembly manual 10 - 2023 8.3. ENELION VERTICA Module with a cable Electrical data Supply voltage (Europe)) 3 x 230 V/400 VAC (+-10%) Voltage frequency 50 Hz/60 Hz TN, TT Network type (IT per request) Overvoltage category III according to EN 60664–1 Rated short-circuit current Effective value <...
  • Page 47: Technical Description

    Vertica - assembly manual 10 - 2023 9. Technical description 9.1. Form with boxes to fill in Charging Station/General Access Charging Station Charging point, an element of public road transport infrastructure Type ENELION VERTICA Pole Model Number ................Module Model Number ................
  • Page 48 © 2023 ENELION Pana Tadeusza 50, 80-123 Gdańsk, Poland...