Smart Event - HIKVISION DS-2CD3956G2-IS(U) User Manual

Table of Contents

Advertisement

Network Disconnected
The device is offline.
IP Address Conflicted
The IP address of current device is same as that of other device in the network.
Illegal Login
Incorrect user name or password is entered.
Abnormal Restart
The device restarts abnormally.
3. Refer to Linkage Method Settings for setting linkage method.
4. Click Save.
Set Alarm Input
Alarm signal from the external device triggers the corresponding actions of the current device.
Before You Start
Make sure the external alarm device is connected. See Quick Start Guide for cable connection.
Steps
1. Go to Configuration → Event → Basic Event → Alarm Input .
2. Check Enable Alarm Input Handling.
3. Select Alarm Input NO. and Alarm Type from the dropdown list. Edit the Alarm Name.
4. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for
setting linkage method.
5. Click Copy to... to copy the settings to other alarm input channels.
6. Click Save.

2.6.2 Smart Event

Set smart events by the following instructions.
Note
For certain device models, you need to enable the smart event function on VCA Resource page
first to show the function configuration page.
The function varies according to different models.
Detect Audio Exception
Audio exception detection function detects the abnormal sound in the scene, such as the sudden
increase/decrease of the sound intensity, and some certain actions can be taken as response.