Graco XM PFP Repair Parts page 17

Hide thumbs Also See for XM PFP:
Table of Contents

Advertisement

5. Disconnect air line.
6. Remove gauge (606) from block (601e).
7. Remove screws from quick clamps (601f) holding air
regulator assembly (601c) in place.
8. Open clamps (601f) at hinge and pull apart from
block (601e).
626
619
638
635
618
630
640 631
F
. 5
IG
3A2989B
617
607
613
603
632
637
636
632
625
628
629
633
627
618
627
9. Remove regulator assembly (601d) and replace with
new. See part number shown in the System Air
Controls Module (255761) section beginning on
page 43.
10. Follow steps in reverse order to reassemble.
11. Set new air pressure regulator to at least 80-85 psi