Consumption
Lube oil consumption after 1000 h runtime
Table 7: Consumption
Model-related data (basic design)
Operating method: Four-stroke cycle, Otto engine, single-acting
Combustion method: Mixture charging, spark ignition
Number of cylinders
Cylinder configuration: V angle
Bore
Stroke
Displacement of a cylinder
Total displacement
Compression ratio
Standard housing connecting flange (engine main PTO)
Table 8: Model-related data (basic design)
Coolant system (HT circuit, referenced to max. power without HT heat recovery)
Coolant temperature (at engine connection: outlet to cooling equipment)
(w/o antifreeze)
Coolant temperature (at engine connection: inlet from cooling equipment)
(w/o antifreeze)
Coolant temperature after engine, warning
Coolant temperature after engine, shutdown
Coolant temperature for release of load application, max. 10 kWmech/
cylinder
Coolant temperature for release of load application, > 10 kWmech/cylin-
der
Coolant antifreeze content, max.
Coolant pump: Volumetric flow
Filling pressure in cooling system (cold)
Pressure in cooling system, max.
Pressure loss over engine with maximum flow rate
Table 9: Coolant system (HT circuit, referenced to max. power without HT heat recovery)
Coolant system (LT circuit, referenced to max. power without HT heat recovery)
Coolant temperature before mixture cooler (at engine connection: inlet
from cooling equipment) (w/o antifreeze)
Coolant antifreeze content, max.
Coolant pump: Volumetric flow
A
A
R
L
L
L
L
L
R
L
A
L
A
MS150121/02E 2017-09 | Technical Data | 29
g/kWh
0.3
X
X
16
Degrees (°)
90
mm
170
mm
210
Liters
4.77
Liters
76.27
10.5
SAE
00
°C
90
°C
78
°C
95
°C
98
°C
40
°C
65
%
50
m³/h
80
bar
0.5
bar
6.0
bar
3.1
°C
53
%
50
m³/h
27

Advertisement