1.4520.591 – MIC5 IPE Prim Short Circuit Cyl 2
Red alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 2 in ignition sequence.
1.4520.592 – MIC5 IPE Prim Short Circuit Cyl 3
Red alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 3 in ignition sequence.
1.4520.593 – MIC5 IPE Prim Short Circuit Cyl 4
Red alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 4 in ignition sequence.
1.4520.594 – MIC5 IPE Prim Short Circuit Cyl 5
Red alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 5 in ignition sequence.
1.4520.595 – MIC5 IPE Prim Short Circuit Cyl 6
Red alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 6 in ignition sequence.
1.4520.596 – MIC5 IPE Prim Short Circuit Cyl 7
Red alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 7 in ignition sequence.
1.4520.597 – MIC5 IPE Prim Short Circuit Cyl 8
Red alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 8 in ignition sequence.
Corrective action
1. Check cabling to ignition coil (→ Page 202).
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil (→ Page 202).
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil (→ Page 202).
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil (→ Page 202).
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil (→ Page 202).
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil (→ Page 202).
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil (→ Page 202).
2. Check ignition coil.
MS150121/02E 2017-09 | Troubleshooting | 97