Removing The Sfp/Sfp+ Transceiver - Planet IXT-900-1X1UP User Manual

Industrial 10g managed media converter
Table of Contents

Advertisement

MGB-TLA80
1000
MGB-TLB80
1000
MGB-TSA
1000
MGB-TSB
1000
MGB-TLA120
1000
MGB-TLB120
1000
It is recommended to use PLANET SFP on the Industrial 10G Managed Media Converter.
1.
If you insert an SFP/SFP+ transceiver that is not supported, the Industrial 10G Managed
Media Converter will not recognize it.
Before we connect the Industrial 10G Managed Media Converter to the other network device, we have to make sure both
1.
sides of the SFP transceivers are with the same media type, for example: 10GBASE-SX to 10GBASE-SX, 1000BASE-LX
to 1000BASE-LX.
Check whether the fiber-optic cable type matches with the SFP transceiver requirement.
2.
To connect to 1000BASE-SX SFP transceiver, please use the multi-mode fiber cable with one side being the male
duplex LC connector type.
To connect to 1000BASE-LX SFP transceiver, please use the single-mode fiber cable with one side being the male
duplex LC connector type.
Connect the fiber cable
Insert the duplex LC connector into the SFP/SFP+ transceiver.
1.
Connect the other end of the cable to a device with SFP/SFP+ transceiver installed.
2.
Check the LNK/ACT LED of the SFP/SFP+ slot on the front of the Industrial 10G Managed Media Converter. Ensure that
3.
the SFP/SFP+ transceiver is operating correctly.
Check the Link mode of the SFP/SFP+ port if the link fails. To function with some fiber-NICs or Media Converters, user
4.
has to set the port Link mode to "10G FDX", "1000M FDX" or "100M FDX".

2.3.2 Removing the SFP/SFP+ Transceiver

Make sure there is no network activity by consulting or checking with the network administrator. Or through the
1.
management interface of the media converter/converter (if available) to disable the port in advance.
Remove the fiber optic cable gently.
2.
Turn the lever of the SFP transceiver to a horizontal position.
3.
Pull out the module gently through the lever.
4.
Never pull out the module without pulling the lever or the push bolts on the module. Directly pulling
out the module with force could damage the module and SFP module slot of the device.
LC
Single-mode
LC
Single-mode
LC
Single-mode
LC
Single-mode
LC
Single-mode
LC
Single-mode
31
User's Manual of IXT-900 PoE series
80km
1490nm
80km
1550nm
2km
1310nm
2km
1550nm
120km
1490nm
120km
1550nm
-40 ~ 85℃
1550nm
-40 ~ 85℃
1310nm
1550nm
-40 ~ 85℃
-40 ~ 85℃
1310nm
-40 ~ 85℃
1550nm
-40 ~ 85℃
1310nm