(3) Combined operation mode 1 (Pr. 79 "operation mode selection" = 3)
The start signal is an external signal.
The frequency setting signal is set using the optional operation
panel or parameter unit.
Preparation
• Start signal ....................... Switch, relay, etc.
• Operation unit .................. Operation panel (FR-PA02
• Connection cable ............. Refer to (2) PU operation mode.
• FR-E5P (option) ............... Refer to (2) PU operation mode.
(4) Combined operation mode 2 (Pr. 79 "operation mode selection" = 4)
The start signal is entered from the operation command key
of the optional operation panel.
The frequency setting signal is set using the external
frequency setting signal.
Preparation
• Frequency setting signal .. 0 to 5V, 0 to 10V or 4 to 20mA
• Operation unit .................. Operation panel (FR-PA02
• Connection cable ............. Refer to (2) PU operation mode.
• FR-E5P (option) ............... Refer to (2) PU operation mode.
parameter unit (FR-PU04)
DC signals from an external
potentiometer or from outside
the inverter
or parameter unit (FR-PU04)
49
OPERATION/CONTROL
) or
-02
)
-02
3