Data line filter
Noise entry can be prevented by providing a data line filter for the detector or other
cable.
Example of counter measures against noise
FR-BLF
Install filter
FR-BSF01
to inverter input side.
Inverter
power supply
Install radio noise filter
to inverter input side.
Separate inverter and power line by more
than 30cm (11.81inches) and at least
10cm (3.94inches) from sensor circuit.
Control power
supply
Do not ground control
box directly.
Do not ground control cable.
Control box Reduce carrier frequency.
FR-
Inverter
BSF01
Power supply
for sensor
38
INSTALLATION AND WIRING
Install filter
inverter output side.
FR-
BSF01
Use 4-core cable for motor power
cable and use one wire as ground
cable.
Use twisted pair shielded cable.
Sensor
Do not ground shield but connect it to signal
common cable.
FR-BLF
to
FR-BSF01
Motor
IM