<Setting>
In the following table, operation using the operation panel or parameter unit is
abbreviated to PU operation.
Pr. 79
Setting
When power is switched on, the external operation mode is selected.
0
PU or external operation can be selected by pressing the keys of the operation panel or
parameter unit. (Refer to page 60) For these modes, refer to the setting 1 and 2 below.
Operation mode
1
PU operation
mode
External
2
operation mode
External/PU
3
combined
operation mode 1
External/PU
4
combined
operation mode 2
Switch-over mode
6
Switch-over between PU and external operation modes can be done while running.
External operation mode (PU operation interlock)
MRS signal ON ......... Able to be switched to PU operation mode (output stop
7
MRS signal OFF ........ Switching to PU operation mode inhibited
Switching to other than external operation mode (disallowed during operation)
8
X16 signal ON ........... Switched to external operation mode
X16 signal OFF.......... Switched to PU operation mode
Note: 1. Either "3" or "4" may be set to select the PU/external combined operation.
These settings differ in starting method.
2. The stop function (PU stop selection) activated by pressing
(operation panel/FR-PU04) is valid even in other than the PU operation mode
when shipped from the factory. (Refer to page 110.)
Function
Running frequency
Digital setting by the key operation
of the operation panel or parameter
unit
External signal input (across
terminals 2 (4)-5, multi-speed
selection)
Digital setting by the key operation of
the operation panel or parameter
unit, or external signal input (multi-
speed setting only)
External signal input (across
terminals 2 (4)-5, multi-speed
selection)
during external operation)
114
PARAMETERS
Start signal
(
,
) key of
FWD
RUN
REV
operation panel or
key of parameter unit
REV
External signal input
(terminal STF, STR)
External signal input
(terminal STF, STR)
(
,
) key of
FWD
RUN
REV
operation panel or
key of parameter unit
REV
STOP
of the PU
RESET
or
FWD
or
FWD