Graco LD Series Instructions Manual page 10

Hose reels
Hide thumbs Also See for LD Series:
Table of Contents

Advertisement

Installation
1
5 ft (1.5m) minimum for motor oil
2
6 ft (1.9m) minimum for 1 lift
3
Center between two lifts
F
. 5
IG
5. Connect inlet supply line to inlet hose of the reel.
See Hose Installation, page 15.
NOTE:
None of the hose reels listed in this manual come
with a Hose Inlet Kit.
6. Flush system.
To avoid contaminating the fluid with line-scale,
chips or other installation debris, before installing
meter or dispense valve to end of hose, flush the
equipment with a compatible solvent such as Stod-
dard solvent or mineral spirits.
a. Secure the end of the hose in a waste bucket.
b. Blow out entire lubricant supply line with air.
c. Pump solvent through line until fluid runs clear
and is debris free.
10
1
3
2
ti13351
d. Pump lubricant through line until all solvent is
flushed out.
7. For enclosed channel installations, continue with
instructions on page 18. For all other installations,
continue Step 8.
8. Position hose stop so hose extends far enough for
all operators to reach dispensing valve and tighten
nuts to securely hold hose stop in place.
9. Install meter or dispense valve to end of hose follow-
ing instructions provided with the dispense equip-
ment. (NOTE: If installing an enclosure around hose
reel, install the enclosure before installing dispense
valve or meter to hose end.)
10. Adjust spring tension, page 16.
313431A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sd seriesXd series