DSX-1-to-V.35 Configuration

To connect a V.35-compatible unit on the CP side and a DSX-1-compatible unit
on the CO side, configure the units as follows. Terminal mode factory defaults are
in bold (for Switchpack mode defaults, see
7924-A2-GB20-20
Configuration
V.35-Compatible Unit
Option
(Customer Premises)
Card Type
CP
Loops Enabled
Dual (Loops A & B) or
Single (Loop A)
Payload Rate
1 – 9 (64 – 1536 Kbps)
Options 8 (1024) and 9 (1536
kbps) are only available if both
Loops A & B are enabled.
N/A
Framing
N/A
T1 Line Encode
N/A
Line Build-Out
August 1997
Appendix
C).
DSX-1-Compatible Unit
(Central Site)
CO
Must be same as CP side
N/A
Use D4, Extended Superframe, or
Unframed. See
Unframed
Operation
on page A-4 before
selecting Unframed.
B8ZS or AMI
Enter 5 at the Config command
prompt. Select from the following
options:
1) 0 to 133 ft
2) 133 to 255 ft
3) 266 to 399 ft
4) 399 to 533 ft
5) 533 to 699 ft
Worksheets