Testing

Starting and Stopping Loopbacks

7-4
To start or stop a local loopback test, enter 5 at the Command prompt.
Command
5
Local Loopback is Enabled!
Command
5
Local Loopback is Disabled!
To start or stop a remote loopback test, enter 6 at the Command prompt.
Command
6
Remote Loopback is Enabled!
Command
6
Remote Loopback is Disabled!
When you stop a loopback test (local or remote), both units automatically
reset themselves in order to return to normal operation.
A loopback may not be started on units that have just been reset. After a
reset, the units require approximately one minute for the circuit (HDSL
connection) to stabilize. If you attempt to start a loopback during this time, the
following error message appears: "PLEASE WAIT! Circuit is stabilizing."
Only one loopback may be run at a time. If a loopback is already enabled, the
following error message appears and no other loopback may be started until
the first loopback is disabled: "CANNOT EXECUTE COMMAND! Current
loopbacks must be removed first."