Buffalo TeraStation WSS 5020N6 User Manual page 112

Network attached storage
Table of Contents

Advertisement

Chapter 6 Drive Replacement
13
When the "Initialize Disk" window appears, make sure the drive number that you have replaced is displayed in
the "Selected disks" field and "GPT" is selected, then click OK.
14
Right-click the initialized drive and select Convert to Dynamic Disk. A volume cannot be created unless the
drive is converted to a dynamic disk.
15
Select the step depending on your reason for a created volume.
Procedure for a RAID 5 Volume
(1) Right-click the volume labeled "Failed Redundancy" and click Repair Volume.
(2) When "Select one of the disks listed below. " is displayed, select the drive to repair and click Yes.
(3) Repeat steps (1) and (2) for each volume that requires resynchronization.
(4) Right-click the volume labeled "Missing" and select Remove Disk.
Procedure for a Mirrored Volume
(1) Right-click the volume labeled "Failed Redundancy" and click Remove Mirror.
(2) When "Remove Mirror" is displayed, select "Missing" and click Remove Mirror.
(3) When "Are you sure you want to remove the mirror?" is displayed, click Yes.
(4) Repeat steps (1) to (3) for each volume that requires resynchronization.
111

Advertisement

Table of Contents
loading