Chapter 6 Drive Replacement
14
Click Tools > Computer Management.
15
Click Disk Management. Make sure the status of the system area shows "Healthy". Creating system area will take
about an hour to complete.
16
Select the step depending on your reason for a created volume.
Procedure for a RAID 5 Volume
(1) Right-click the volume labeled "Failed Redundancy" and click Repair Volume.
(2) When "Select one of the disks listed below. " is displayed, select the drive to repair and click OK.
(3) Repeat steps (1) and (2) for each volume that requires resynchronization.
(4) Right-click the volume labeled "Missing" and select Remove Disk.
108