Electrical connection

Attention!
The electrical connection of the equipment must only be carried out by
officially qualified and skilled personnel!
Attention!
It is absolutely necessary to ground the ExCam
PA connection.
Attention!
The minimum length of the connecting cable must not be less than
three meters! The connection cable must be protected!
Attention!
Please pay attention to the national security, installation and accident
prevention regulations (e.g. DIN EN 60079-14) and the safety instruc-
tions given below in this User Manual, as well as the ones in the Instal-
lation Guidelines!
®
The ExCam
IPP3827 is equipped with an electrical connection cable of the type
(A)SKD02-T (models ...-P/T) or optionally with a flipConnect for the electrical connection.
The maximum transmission range from the camera to the next active network interface is
100 meters and can be individually specified by the client. The user is NOT authorised to
do electrical connection procedures inside the pressure-resistant enclosure.
5.1

Equipotential bonding/Grounding

®
series housing via the
Figure 5-1 ExCam IPP3827 equipotential bonding
Doc.-ID: 230802-PT08BA-ES-ExCam-IPP3827_en_rev.00.docx, Page 12 of 32