Change Options/Display Options (cho/dso) Commands
The following changes and additions apply to both the Change Options (cho) and Display Options
(dso) commands.
For the DualFlow DSU and the TDM/Flex or MCMP/Flex options for a DSU:
For the 3900 Series modems:
The Port n Configuration Set for DSUs with TDM/MCMP and the General Configuration
Set for DSUs with the ASPEN application module, but no TDM/MCMP, input forms have
the following new field: Overspeed. A pop-up menu is available listing valid selections.
The DBM Configuration Set input form has the following valid selections for the DTR call
control field: disable, originate and answer.
The Port Speed Configuration Set input form has the following new selections for the DDS
rate (Kbps) and DDD rate (Kbps) fields: 4.4, 9.2, and 18.8 (Kbps).
The Port Configuration Set input form has the following new selections for the DSU port
rate selection (Kbps) and DBM port rate selection (Kbps) fields: 4.4, 9.2, and
18.8 (Kbps).
The Configuration Set input form has new pages to support both the DualFlow DSU and the
DualFlow DBM.
— For the DualFlow DSUs: DSU Configuration Set screen, Diagnostic Configuration Set
screen, and DSU port Configuration Set screen. On all three screens, a pop-up menu is
available listing valid selections.
— For the DualFlow DBMs: DBM Configuration Set screen, Backup Configuration Set
screen, Diagnostic Configuration Set screen, and DBM port Configuration Set screen.
On all three screens, a pop-up menu is available listing valid selections.
The DTE INTERFACE Configuration Set input form has one new selection for the DTR
action field:
— CntrlsTxMute
This screen also has two new fields: Extend Main ch. and Upstream port.
The DIAL LINE Configuration Set input form has the following new field: V32bis
override.
The LEASED LINE Configuration Set input form has six new fields. A pop-up menu is
available listing valid selections.
— V32bis override
— Special standby
— Dial standby time
— Lease lookback
— Dual lease line
— Backup line check
8

Advertisement

loading

This manual is also suitable for:

3920plus3921plusComsphere 6800 series