Installing/mounting
5.9 Necessary tools
Recommended inlet
Pumps
Single bends
Recommended outlet
Note
By more than one bend, the optimal inlet is min. 40 × pipe diameter.
5.8

General information

Installation and assembly of the FSS100 retrofit sensor kit occurs in 5 steps:
1. Calculating the transducer holder position
2. Installing the transducer holders
3. Determining sensor data
4. Connecting the transducer
5. Entering the transducer geometry data into the transmitter
Note
Step 5 is only described in the relevant transmitter Operating Instructions
5.9

Necessary tools

Basic tools
• Angle iron of a length approximately corresponding to the outer diameter of the pipe
• Measuring tape
• Scriber, pencil or the like
• Pocket calculator
• Calipers
• Sliding gauge
• Hammer
• Centre punch
• Spirit level
• Roll of adhesive tape
36
 
Min. 20 × pipe diameter
Min. 10 × pipe diameter
3 × pipe diameter