Installing/mounting
5.10 Installation instructions
3. Remove the paper.
Note
When preparing a steel pipe, it is useful to draw a circle with a radius of 30 mm around points
P using the centre punch. This facilitates cutting the holes with a flame cutter.
46
Installation Manual, 12/2023, A5E52595000-AA