Siemens SITRANS FSS100 Installation Manual page 82

Ultrasonic flowmeters
Table of Contents

Advertisement

Technical specifications
8.6 FS130 wall housing and external DSL
Description
MLFB SITRANS FST030
Measurement paths
 
1 path measurement
Sensor
Pipe size
Measurement accuracy at flow rate
Repeatability ISO 11631
 
2 path measurement
Sensors
Pipe size
Measurement accuracy at flow rate
Repeatability ISO 11631
 
3 path measurement
Sensors
Pipe size
Measurement accuracy at flow rate
Repeatability ISO 11631
 
4 path measurement
Sensors
Pipe size
Measurement accuracy at flow rate
Repeatability ISO 11631
Wall thickness steel pipe
Wall thickness of concrete pipe
82
Specification
7ME3721-0AA00-0VX3-Z B11...
M12 plug connection FS DSL
1 to 4 paths
2 transducers
Min. DN 100 (4") up to DN 400 (16")
recommended
+/-1 - 3%
0,5 m/s < v < 10 m/s
Without calibration
< 0,25%
4 transducers
Min. DN 100 (4") up to DN 1200 (48")
recommended
+/-0,5 - 1,5%
0,5 m/s < v < 10 m/s
Without calibration
< 0,25%
6 transducers
Min. DN 600 (24") up to DN 2400 (96")
recommended
+/-0,5 - 1,5%
0,5 m/s < v < 10 m/s
Without calibration
< 0,25%
8 transducers
Min. DN 300 (12") up to DN 2400 (96")
recommended
+/-0,5 - 1,5%
0,5 m/s < v < 10 m/s
Without calibration
< 0,25%
Up to 20 mm (0,79")
Up to 200 mm (7,9") > DN 600
Installation Manual, 12/2023, A5E52595000-AA
SITRANS FSS100

Advertisement

Table of Contents
loading

This manual is also suitable for:

7me381

Table of Contents