Technical specifications
8.6 FS130 wall housing and external DSL
Description
MLFB SITRANS FST030
Measurement paths
1 path measurement
Sensor
Pipe size
Measurement accuracy at flow rate
Repeatability ISO 11631
2 path measurement
Sensors
Pipe size
Measurement accuracy at flow rate
Repeatability ISO 11631
3 path measurement
Sensors
Pipe size
Measurement accuracy at flow rate
Repeatability ISO 11631
4 path measurement
Sensors
Pipe size
Measurement accuracy at flow rate
Repeatability ISO 11631
Wall thickness steel pipe
Wall thickness of concrete pipe
82
Specification
•
7ME3721-0AA00-0VX3-Z B11...
•
M12 plug connection FS DSL
1 to 4 paths
2 transducers
Min. DN 100 (4") up to DN 400 (16")
recommended
•
+/-1 - 3%
•
0,5 m/s < v < 10 m/s
•
Without calibration
< 0,25%
4 transducers
Min. DN 100 (4") up to DN 1200 (48")
recommended
•
+/-0,5 - 1,5%
•
0,5 m/s < v < 10 m/s
•
Without calibration
< 0,25%
6 transducers
Min. DN 600 (24") up to DN 2400 (96")
recommended
•
+/-0,5 - 1,5%
•
0,5 m/s < v < 10 m/s
•
Without calibration
< 0,25%
8 transducers
Min. DN 300 (12") up to DN 2400 (96")
recommended
•
+/-0,5 - 1,5%
•
0,5 m/s < v < 10 m/s
•
Without calibration
< 0,25%
Up to 20 mm (0,79")
Up to 200 mm (7,9") > DN 600
Installation Manual, 12/2023, A5E52595000-AA
SITRANS FSS100