Siemens SITRANS FSS100 Installation Manual page 84

Ultrasonic flowmeters
Table of Contents

Advertisement

Technical specifications
8.7 FS130 industrial housing and external DSL
Description
Measurement paths
 
1 path measurement
Sensor
Pipe size
Measurement accuracy at flow rate
Repeatability ISO 11631
 
2 path measurement
Sensors
Pipe size
Measurement accuracy at flow rate
Repeatability ISO 11631
 
3 path measurement
Sensors
Pipe size
Measurement accuracy at flow rate
Repeatabilityt ISO 11631
 
4 path measurement
Sensors
Pipe size
Measurement accuracy at flow rate
Repeatability ISO 11631
Wall thickness steel pipe
Wall thickness of concrete pipe
Cable length sensor to FS DSL
Connection sensor to FS DSL
84
Specification
1 to 4 paths
2 transducers
Min. DN 100 (4") up to DN 400 (16")
recommended
+/-1 - 3%
0,5 m/s < v < 10 m/s
Without calibration
< 0,25%
4 transducers
Min. DN 100 (4") up to DN 1200 (48")
recommended
+/-0,5 - 1,5%
0,5 m/s < v < 10 m/s
Without calibration
< 0,25%
6 transducers
Min. DN 600 (24") up to DN 2400 (96")
recommended
+/-0,5 - 1,5%
0,5 m/s < v < 10 m/s
Without calibration
< 0,25%
8 transducers
Min. DN 300 (12") up to DN 2400 (96")
recommended
+/-0,5 - 1,5%
0,5 m/s < v < 10 m/s
Without calibration
< 0,25%
Up to 20 mm (0,79")
Up to 200 mm (7,9") > DN 600
Min. 3 m
Max. 15 m
Analog
Installation Manual, 12/2023, A5E52595000-AA