Anchor Type - Static; Anchor Specifications; Pullout Force; Tools Required - LifeFitness LBR-AC Assembly Instructions Manual

Abdominal crunch bench
Table of Contents

Advertisement

Anchor Type - Static

Static Anchor

Anchor Specifications

Static Anchor
KH-EZ 1/4"
HUS-H 6mm

Pullout Force

Life Fitness specifies Hilti
design pullout force (in tension) for the specified anchors, when properly installed in cracked concrete, is provided in
the side table. This table should be used for reference only; for additional and up-to-date information on the anchor
capabilities or the design pullout force in other substrates, please consult Hilti directly at https://www.us.hilti.com.
Selected Anchor
KH-EZ 1/4" x 4"
HUS-H 6MM x 120MM
KH-EZ 3/8" x 4"
KH-EZ 3/8" x 5"
HUS-H 8MM x 120MM
HUS-H 8MM x 150MM
HSL-3 and HSL4 M 8/40
HST M12 x 115/20
HST M12 x 195/200
KB-TZ 3/8" x 3-3/4"
* Design strength extracted from the Hilti Anchor Fastening Technology Manual.

Tools Required

WARNING: Adhere to manufacturer's equipment warnings and guidelines. Follow manufacturer's instructions
for proper usage.
• 1" L-shape SDS rotary hammer
• (Imperial anchors) 3/8" diameter carbide drill bit
• (Metric anchors) 10mm diameter carbide drill bit
• Extension cord
• Floor scanner / rebar detector (optional)
• Hammer (Dynamic anchors only)
• Rotary tool
• Safety glasses
• Tape measure
• Torque wrench
Minimum Concrete
Minimum Drill Depth
Thickness
4-1/8" (105mm)
3-3/32" (100mm)
static and dynamic anchors. According to the anchor manufacturer, the recommended
Standard Sizes
Imperial: KH-EZ 3/8" x 5"
Metric: HUS-H 10mm x 130mm
Minimum Concrete
in Concrete
1/2" (12.7mm)
2-1/2" (63.5mm)
beyond anchor
length
25/64" (10mm)
2-1/64" (55mm)
beyond anchor
length
Design Resistance in Tension *
Page 18 of 21
Minimum concrete
Embedment
compressive strength
3000psi (20 N/mm2)
3000psi (20 N/mm2)
830 lb
3.3 kN
1535 lb
1535 lb
3.3 kN
3.3 kN
2000 lb
8 kN
8 kN
1615 lb
Drill Bit Size
3/8in
10mm

Advertisement