Configuring the Unit Using the Internal
Switches
You can use the internal switches to manually configure the unit.
!
HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components
from damage due to electrostatic discharge (ESD) during
normal operation. When performing installation
procedures, however, take proper static control precautions to
prevent damage to equipment. If you are not sure of the
proper static control precautions, contact your nearest
sales or service representative.
Procedure
To configure the unit using internal Switchpack S3:
1
Power off the unit.
2
Remove the enclosure cover:
— Use a Phillips screwdriver to remove the two screws from the top of the unit.
— Push a flat-blade screwdriver through the slots on both sides of the housing to free the
four inner latches.
3
Locate Switchpack S3 on the circuit board using
Switchpack
Locations.
4
Set Switch 6 on Switchpack S3 to ON to enable the switchpack.
5
Set the switches to your desired configuration:
— For Model 7995, refer to
— For Model 7996, refer to
6
Replace the cover and fasten it with the two screws.
7
Power on the board to reset the unit and enable the new configuration.