Table 6:
Communication Port Options (2 of 3)
Data Rate
Possible Settings: 9.6, 14.4, 19.2, 28.8, 38.4, 57.6, 115.2
Default Setting: 9.6
Specifies the communication port baud rate.
Character Length
Possible Settings: 7, 8
Default Setting: 8
Determines the character length of the communication port.
Parity
Possible Settings: None, Odd, Even
Default Setting: None
Specifies the parity of the communication port.
Stop Bits
Possible Settings: 1, 1.5, 2
Default Setting: 1
Specifies the number of stop bits for the communication port.
Ignore Control Leads
Possible Settings: Disable, DTR
Default Setting: Disable
Specifies whether DTR is used.
Login Required
Possible Settings: Enable, Disable
Default Setting: Disable
Specifies whether an ID and password are required to access the asynchronous terminal
interface on the communication port when Port Use is set to Terminal. Login IDs are created
with a password and access level.
Port Access Level
Possible Settings: Administrator, Operator
Default Setting: Administrator
Specifies the highest level of access allowed when accessing an ATI session through a Telnet
session when Port Use is set to Terminal.