9 Installation in piping

9.4 Installation with clamp connections

Fig. 2: Clamp connection
Gasket and clamp
▶ The gasket and clamps for clamp connections are not in-
cluded in the scope of delivery.
1. Insert the corresponding gasket between the connection
adapter and the pipe connection.
2. Connect the gasket between the connection adapter and
the pipe connection using clamps.
GEMÜ P600S
NOTICE

9.5 Installation with flanged connection

Fig. 3: Flanged connection
Sealing material
▶ The sealing material is not included in the scope of deliv-
ery.
Only use appropriate sealing material.
Connector elements
▶ The connector elements are not included in the scope of
delivery.
Only use connector elements made of approved materi-
als.
Observe permissible tightening torque of the bolts.
1. Ensure clean, undamaged sealing surfaces on the connec-
tion flanges.
2. Align flanges carefully before installing them.
3. Centre the gaskets.
4. Connect the valve flange and the piping flange using ap-
propriate sealing materials and matching bolting. Sealing
material and bolts are not included in the scope of deliv-
ery.
5. Use all flange holes.
6. Only use connector elements made of approved materials!
7. Tighten the bolts diagonally.
Observe appropriate regulations for connections!
After the installation:
- Re-attach or reactivate all safety and protective devices.
20 / 31