Please use this procedure only when network primary controller is
missing or otherwise inoperable.
Adding a Yale Z-Wave Plus™ v2 Smart Module to your Assure Lock & Z-Wave™ System
1. Install Yale Smart Module into slot above battery compartment
IMPORTANT: Batteries must be removed before inserting Yale Smart Module:
• Remove battery cover
• Remove batteries
• Insert Yale Smart Module
• Reinstall batteries
• Reinstall battery cover
2. Open Z-Wave™ system's smart home or alarm app on your smartphone or tablet
3. If you have SmartStart* enabled with your Z-Wave™ System follow in-app prompts to add a
new device If you don't have SmartStart or are not sure, follow steps 4 - 6
4. On your lock keypad, enter your master entry code followed by the
5. Press the 7 key followed by the
6. Press the 1 key followed by the
Removing a Yale Z-Wave Plus™ v2 Smart Module from your Assure Lock & Z-Wave™ System
1. Open Z-Wave™ system's smart home or alarm app and follow instructions for removing a device
2. On your lock keypad, enter your master entry code followed by the
3. Press the 7 key followed by the
4. Press the 3 key followed by the
5. Remove Yale Smart Module from slot above battery compartment
IMPORTANT: Batteries must be removed before removing Yale Smart Module:
• Remove battery cover
• Remove batteries
• Remove Yale Smart Module
• Reinstall batteries
• Reinstall battery cover
6. If you're adding a new Yale Smart Module, follow instructions included with it
*SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a
controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10
minutes of being switched on in network vicinity.
Yale
Z-Wave Plus™ Smart Module
®
®
Installation Guide
icon
icon
icon
icon
If prompted, scan QR code
icon
icon
P/N AYR-MOD-ZW3-MNL-0015 Rev A

Advertisement

Table of Contents
loading

Summary of Contents for Yale real living Z-Wave Plus YRD622-NN-ZW3

  • Page 1 Please use this procedure only when network primary controller is missing or otherwise inoperable. Adding a Yale Z-Wave Plus™ v2 Smart Module to your Assure Lock & Z-Wave™ System 1. Install Yale Smart Module into slot above battery compartment IMPORTANT: Batteries must be removed before inserting Yale Smart Module: •...
  • Page 2 20cm between the radiator & your body. 24/7 Tech Support: 1-855-492-0505 • www.yalehome.com Yale® is a registered trademark of ASSA ABLOY Residential Group. Other products' brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only.
  • Page 3 Touchscreen Deadbolt ( 226/YRD620/YRD622)! If thumbturn operation fails, check installation beginning with Step 7. For more information about Yale Smart modules and smart home features To be used with Fire Cup Using Your Lock instructions will help you customize your lock.
  • Page 4 L = 3-1/2" (88.8mm) Yale® and Assure Lock® are registered trademarks of Yale Home. Yale Accentra™ is a trademark of Yale Home. Exit the Network Here is an example of how to set Auto Lock to 30 seconds:...
  • Page 5 Yale Locks Z-Wave Plus ™ v2 System Integrators Guide Yale Assure Electronic Deadbolts YRD216-ZW3, YRD226-ZW3, YRD256-ZW3, YRC216-ZW3, YRC226-ZW3, YRC256-ZW3, YRD652-ZW3, NF-YRD622-ZW3, NF-YRD612-ZW3, YRC652-ZW3, NF-YRC622-ZW3, NF-YRC612-ZW3, YRD622-ZW3, YRD642-ZW3, YRC622-ZW3, YRC642-ZW3, YRD410-ZW3, YRD420-ZW3, YRD430-ZW3, YRD450-ZW3, YRD622-NN-ZW3, YRD642-NN-ZW3, YRC622-NN-ZW3, YRC642-NN-ZW3 Document Revision: 2.3...
  • Page 6: Table Of Contents

    Contents Revision History ..................4 Yale Z-Wave Plus ™ Product Info ..............6 Network Operations ..................6 Enroll/Add device to network (SmartStart) ........... 6 Enroll/Add device to network (Classic Inclusion Mode) for Assure Lock [YRC/D216/226/256/622/642/652, NF-YRC/D612/622] ........7 Enroll/Add device to network (Classic Inclusion Mode) for Assure 2 Lock [YRD410/420/430/450] ................
  • Page 7 Command Class Application Status, Version 1 ..........32 Command Class Transport Service, Version 2 ..........32 Command Class Supervision, Version 1 ............32 Command Class Indicator, Version 3* ............32 Command Class Basic, Version 2* ............. 33 * This command class requires security.
  • Page 8: Revision History

    Revision History Rev. Details Initial Release Made the following updates: • Added Command Class Clock section. • Added Clock Report to the Association Group Info commands list. • Marked Time as a secure command class. • Added the following note to Time, Time Parameters, and Clock command classes: “If the controller does not support either the Time CC, Time Parameters CC, or Clock CC, then scheduled users will not have access.”...
  • Page 9 • Re-added Scheduling Alarms • Fixed Door State Alarm value • Added -NN (No NFC) SKUs • Added Handing Alarm • Fixed Master Code Change Alarm • Fixed Wrong Entry Code Limit Alarm • Fixed Auto Relock Time default and minimum for 400 Series Locks •...
  • Page 10: Yale Z-Wave Plus ™ Product Info

    Yale Z-Wave Plus ™ Product Info Manufacturer ID: ASSA ABLOY (0x0129) Z-Wave ™ Device Type: Door Lock Keypad Z-Wave Role Type: Listening Sleeping Slave (LSS) ™ Network Operations Enroll/Add device to network (SmartStart) SmartStart enabled products can be added into a Z-Wave network by scanning the ™...
  • Page 11: Enroll/Add Device To Network (Classic Inclusion Mode) For Assure Lock [Yrc/D216/226/256/622/642/652, Nf-Yrc/D612/622]

    When the Yale lock is unenrolled/excluded from the network through the device menu mode, any changes previously made to the user code database and configuration settings will be retained, as opposed to set back to defaults.
  • Page 12: Factory Reset

    The supported command classes are listed below, and certain sections contain details about operations that may be specific to the Yale lock. If a section is blank, then please refer to the Z-Wave ™...
  • Page 13: Command Class Manufacturer Specific, Version 2

    ZW2 and ZW3. See Table 1 - First 2 Digits of Product ID, below, for details. o Product IDs for the locks covered in this document are as follows: 0x4600 for older version of Yale Residential Deadbolt Lock ▪ 0x46D1 for YRD216-ZW3 (Keyed Push Button Deadbolt) ▪...
  • Page 14 0x45D1 for YRD410-ZW3 (2nd Generation Assure Keyed Push ▪ Button Deadbolt) 0x45D2 for YRD420-ZW3 (2nd Generation Assure Keyed Touch ▪ Screen Deadbolt) 0x45D3 for YRD430-ZW3 (2nd Generation Assure Keyless Push ▪ Button Deadbolt) 0x45D5 for YRD450-ZW3 (2nd Generation Assure Keyless Touch ▪...
  • Page 15: Command Class Security, Version 1

    Command Class Device Reset Locally, Version 1* * This command class requires security. The Yale door locks covered in this guide can be reset to their factory default settings by manually resetting the lock or by BLE command via app for BLE locks (by following the procedure outlined in the specific lock’s manual).
  • Page 16: Command Class Power Level, Version 1

    Command Class Version, Version 3* * This command class requires security. The Yale Real Living locks are a multi-processor system with 1 additional firmware target. All processors can be updated through the Firmware Update Meta Data command class. The firmware targets are numbered as follows: •...
  • Page 17: Command Class Battery, Version 1

    3.8V for Product Type IDs 0x8002 & 0x8004 and starting at about 4.2V for Product Type ID 0x8109, 0x810A, 0x8103, 0x8104 & 0x8113). In addition, the Yale Locks provide 2 earlier low battery alarms through the notification command class (see Table 7 - Notification Table).
  • Page 18: Command Class Door Lock, Version 4

    Door Unsecured (0x00), and Door Unsecured with timeout (0x01). When Auto Relock is enabled, the lock will automatically relock after all unlock events. Yale Z- Wave Plus ™ locks do not support any of the “Door Unsecured for outside Door Handles”...
  • Page 19 1 of this command class. For version 2, the Master Code Set/Get/Report commands must be used. Yale locks do not support bulk commands (setting or getting multiple user codes at once) or CRC functionality for this command class. It should be noted that the lock’s operation mode (called “User Code Keypad Mode”...
  • Page 20 Table 3 - User ID Status User Code CC v1 vs v2 User ID Status User Code CC v1 Set User Code CC v1 Report Value Description Value Value Available 0x00 0x00 Enabled / Grant Access 0x01 0x01 0x02 Disabled 0x03 0x03 Messaging:...
  • Page 21 User ID User Code CC v2: Extended User Code CC v2: Extended User Status User Code Set Code Report Value Description Value Value Available 0x00 0x00 Enabled / 0x01 0x01 Grant Access Disabled 0x02 0x02 Messaging: The user code is accepted, but the lock does not grant access to the...
  • Page 22: Command Class Time Parameters, Version 1

    Command Class Time Parameters, Version 1* * This command class requires security. The controller must set the Time Parameters in the lock anytime the lock loses power. After 10 seconds from lock enrollment, if there are no messages from the controller the lock will initially request the Time (by sending Time Get and Time Parameter Get commands).
  • Page 23: Command Class Firmware Update Meta Data, Version 5

    Command Class Firmware Update Meta Data, Version 5* * This command class requires security. Yale Z-Wave Plus ™ locks support over-the-air (OTA) upgrading of 2 firmware targets: 1. Firmware Target 0: Z-Wave chip ™ 2. Firmware Target 1: The lock main processor Firmware Target 0 is used to determine the correct Z-Wave ™...
  • Page 24: Command Class Association, Version 2

    This command class has been implemented per the Z-Wave™ Specification. Command Class Multi Channel Association, Version 3* * This command class requires security. This command class has been implemented per the Z-Wave™ Specification. Yale locks support only one group, which can contain up to 5 nodes.
  • Page 25: Command Class Association Group Info, Version 3

    Command Class Association Group Info, Version 3* * Command Class Requires Security Yale locks support the Lifeline Association Group. Table 5 - Association Table Group ID Maximum Nodes Description Commands • Command Class Battery Battery Report • Command Class Configuration Configuration Report •...
  • Page 26 The following are the actions to trigger the reports: Table 6 – Lifeline Report Trigger Table Report Command RF Trigger Manual Trigger Battery Report Any RF Lock Operation when lock is Any manual/keypad Lock Operation under the battery thresholds when lock is under the battery thresholds or Power Cycle Lock Configuration Report Configuration Set...
  • Page 27: Command Class Notification, Version 8

    Command Class Notification, Version 8* * This command class requires security. Table 7 - Notification Table Alarm Alarm Notification Alarm Reports Description Event type Level Type 0x01 Deadbolt jammed while locking 0x06 0x0B Deadbolt Jammed 0x09 0x02 Deadbolt jammed while unlocking 0x06 0x0B 0x (01 –...
  • Page 28 RF Operate Lock 0x18 0x01 by RF module 0x06 0x03 RF Operate Unlock 0x19 0x01 by RF module 0x06 0X04 Auto Lock Operate 0x1B 0x01 Auto re-lock cycle complete, locked. 0x06 0x09 Locked 0x (01- 0X0D User was deleted. Alarm level = user (single) slot number users)
  • Page 29 0x (01- Daily Repeating Schedule(s) were Daily Repeating 0x61 enabled/disabled for User ID specified in 0x06 0xFE Schedule users) Alarm Level. If Alarm Level = 0xFF then Enabled/Disabled all users were affected. 0x (01- Year Day Schedule Schedule(s) has been set/erased for 0x62 0x06 0xFE...
  • Page 30 0X04 ¹ Deleting all user codes will also delete any associated schedules (year day and daily repeating scheduled pin codes) assigned to user codes. ² Only supported by YRD410/420/430/450. This requires additional Hardware and calibration within the Yale Access App.
  • Page 31 Battery Command Class. This is the last low battery alarm level before the product stops functioning. Starting at 3.8V (0x8002 & 0x8004); 4.2V (0x8109 ,0x810A, 0x8103 ,0x8104, & 0x8113) ⁴ Only supported by YRD410/420/430/450 and needs Yale Access App setup.
  • Page 32: Command Class Configuration, Version 4

    Command Class Configuration, Version 4* * This command class requires security. Table 8 - Configurable Parameters Length of Info Configuration Properties Info String (Max length Param. allowed Num. Name Length Default is 90) 0x02 (Low Volume) Set Volume Level to [0x8002, high (1), low (2), or 0x8109,...
  • Page 33 0x0A (10 seconds) [0x8002, 0x810A, 0x8004, 0x8109, 0x8103 & 0x8113] 0x01 (1 seconds) 0xB4 (180 0x1E (30 Adjust the time your Relock time 1 byte [0x8104] ¹ seconds) seconds) lock will auto relock. 0x05 [0x8002, 0x810A, 0x8004, 0x8109, 0x8103 & Adjust the limit for 0x8113] wrong code entries...
  • Page 34 Set the Operating Mode to normal mode(0), vacation mode(1), privacy 0x02 (Privacy mode(2). [0x8002, Mode) 0x8004, 0x8109 & [0x8002, 0x810A] 0x8004, Set the Operating 0x8109 & Mode to normal 0x810A] Operating mode 0x00 (Normal 0x00 (Normal 1 byte mode, keypad ³...
  • Page 35 Relock feature) and 11 (One Touch Locking feature). ⁷ Only supported by YRD410/420/430/450. This requires additional Hardware and calibration within the Yale Access App. ⁸ The Door Propped value is represented as seconds X 10. (i.e., a value of 4 would mean a door propped timer of 40...
  • Page 36 Command Class Application Status, Version 1 This command class has been implemented per the Z-Wave ™ Specification. Command Class Transport Service, Version 2 This command class has been implemented per the Z-Wave ™ Specification. Command Class Supervision, Version 1 This command class has been implemented per the Z-Wave ™...
  • Page 37 Command Class Basic, Version 2* * This command class requires security. This command class is mapped to Door Lock CC: Table 11 – Basic Mapping Overview Basic Command Door Lock Mapped Command Basic Set (Value) Door Lock Operation Set (Door Lock Mode) Basic Report (Current Value = 0x00) Door Lock Operation Report (Door Lock...

Table of Contents