Yale real living Z-Wave Plus YRD622-NN-ZW3 Installation Manual page 4

Smart module
Table of Contents

Advertisement

Using Your Lock
Touchscreen Keypad
Press to wake keypad
or lock door
Location of RFID
Signal Receiver
Press to return to
(YRD620/YRD622 ACC ONLY)
previous Settings Menu
Press to enter
Enter Master Entry Code
or unlock
and press to access
Settings Menu
Low Battery
Indicator
All Code Lockout
Indicator
Speaker
Mechanical Key
Backup Entry Method
Inside Lock
Battery Cover
Speaker
Inside Notification
Light
Privacy Button
Thumbturn for
manual locking
and unlocking
Customizing YRD226 Lock
Using Settings Menu
1. Press Yale logo to wake up lock
.
2. Enter Master Entry Code* followed by
icon.
Lock Response: "Welcome to the Settings Menu. Press each number
to hear available settings and then press the settings icon to enter."
3. Enter digit corresponding to the function to be performed followed
by the
icon. Follow the voice commands.
Advanced
Auto Re-lock
Disable
Advanced
Lock Settings
Lock Settings
30 sec
60 sec
2 min
Remain
3 min
in
Settings
Menu
Inside Indicator Light
Enable
or
Disable
Exit
Settings
One Touch Locking
Enable
Menu
Disable
Privacy Button Setting
Enable
Disable
Preforms automatic
Handing the Lock
or
handing of the lock
Volume Setting
High
Low
or
Volume Setting
Silent
Default settings in bold.
Language Setting
English
Spanish
or
Language Setting
French
All Code Lockout
Enable
or
Disable
All Code Lockout
**Network Module Setting
Join the Network
or
**Network Module Setting
Exit the Network
Here is an example of how to set Auto Lock to 30 seconds:
***Configure for Accentra
Master Entry Code
, 3
, 1
, 2
,
*The Master Entry Code must be created prior to any other programming of the lock.
*Master Entry Code must be created prior to any other programming of the lock.
**If Escape Return Mode is enabled, Auto Re-lock cannot be enabled.
**Network Module Setting function appears only with Yale Smart module installed.
***Configuration will disable locking/unlocking via Entry Codes.
Creating Master Entry Code
Creating Entry Codes
Master Entry Code must be created first.
The Master Entry Code is used to change the lock settings.
*Max Entry Codes = 250 with Smart Module; 25 without.
A security best practice is to set your Master Entry Code with 6 or
more digits and create a separate code that is used daily to lock and
unlock the door.
"Register Master
Code. Press the gear
Press
key to continue."
Press
Press
Adding more *Entry Codes:
"Enter a 4 to 8 digit
Enter 4-8 digit
PIN code followed by
Master
Press
the gear key."
Entry Code
Enter 4-8 digit Entry Code
Press
"Registered."
Press
Customizing YRD620/YRD622 ACC
Troubleshooting
ONLY Lock Using Settings Menu
1. Press Yale logo to wake up lock
.
2. Enter Master Entry Code* followed by
icon.
Lock Response: "Welcome to the Settings Menu. Press each number
to hear available settings and then press the settings icon to enter."
3. Enter digit corresponding to the function to be performed followed
by the
icon. Follow the voice commands.
Auto Re-lock
Disable
30 sec
60 sec
2 min
Remain
3 min
in
Settings
Menu
Inside Indicator Light
Enable
or
Disable
Exit
Settings
One Touch Locking
Enable
Menu
Disable
Privacy Button Setting
Enable
Disable
Preforms automatic
Handing the Lock
or
handing of the lock
**Escape Return Mode
Enable
or
Disable
High
Default settings in bold.
Low
or
Here is an example of
Silent
how to set Auto Lock to
English
30 seconds:
Master Entry Code
,
Spanish
or
3
,
French
1
,
2
,
Enable
or
Disable
Join the Network
or
Exit the Network
Use Yale Accentra Configuration app
to complete
Deleting Entry Codes
Enter Master
"Menu Mode,
Entry Code
press the gear key
Press
Enter Master
to continue."
Entry Code
Press
Press
Press
Press
Press
Press
Enter 4-8 digit Entry Code
Press
Press
(code flashes)
Deleting one Entry Code:
To delete one Entry Code,
To delete all Entry Codes
you must enter the Entry
(Does not delete
To end programming:
Code you wish to delete.
Master Entry Code):
Press
Enter 4-8 digit Entry Code
Enter
Press
Press
Hardware Troubleshooting
Thumbturn
with
door open
• If deadbolt does not extend or retract easily when testing thumbturn and keypad
operation, revisit installation steps. It is important that the bolt be in the retracted
position during lock installation and that installation procedure is followed carefully.
• Attempt rehanding using Settings Menu.
Helpful Tip: Ensuring smooth deadbolt operation can enhance your battery life.
If you feel resistance, ensure deadbolt
strike plate aligns with deadbolt. If
deadbolt strike plate is out of alignment,
please attempt to adjust knob/ lever/
handleset strike using steps below. The
knob/lever/handleset latch engagement
into the strike is the main component
used for door alignment.
If deadbolt does not fully extend,
consider increasing depth of deadbolt
strike pocket in frame.
To adjust Knob/Lever/Handleset strike
plate:
1. Remove plate from door frame with a
manual screwdriver. (Using an electric
driver may strip screw heads or
enlarge screw holes.)
Unlocking Door with Entry Codes
"Menu Mode,
enter number,
press the gear key
to continue."
Enter Entry Code
Press
Unlocking Door with RFID
(YRD620/YRD622 ACC ONLY)
See "Customizing YRD620/YRD622 ONLY Lock Using Settings
Menu", to configure RFID communication.
Touch and hold fob or card to
Resetting Lock to Factory Default
Keypad
When lock is reset to factory defaults all Entry
with
Codes (including Master Entry Code*) are
door open
deleted and all programming features are
reset to original default settings (see below).
1. Remove battery cover and batteries.
2. Remove inside lock to access reset button.
3. Reset button (see image at right) is located
beside cable adapter.
4. While pressing reset button (minimum of 3
seconds) reinstall batteries. Release reset
button.
5. Replace battery cover.
Upon reset, Master Entry Code creation is the
only option available and must be performed
prior to any other programming of the lock.
Thumbturn
with
door closed
Replacing Cylinder
1.
To Remove cylinder:
2. Locate strike plate tab.
Tab
A. Remove outside lock from door.
Bend the tab towards
B. Remove rubber gasket.
surface of strike. Note: A
C. Insert small flathead screwdriver under
small change may be all that
spring. Gently lift spring. Note: Notch on
is required.
top of cylinder engages spring.
D. Remove cylinder by pulling outward.
3. Reinstall strike plate using a manual
screw driver and test again.
Before installing cylinder, be sure tailpiece is
correct length (see below).
4. If door cannot be adjusted sufficiently
with strike tab, both
2.
To install new cylinder:
knob/lever/handleset latch and
A. Reverse previous steps for removing
deadbolt latch could require
cylinder.
adjustment – we suggest you contact a
1-3/8"* - 2" thick doors:
local locksmith for assistance.
L = 3-1/2" (88.8mm)
L
For help with misalignments, watch our
2" - 2-1/4" thick doors:
door alignment video:
L = 3-3/4" (95.3mm)
W
US.YaleHome.com/en/support/yale-
T
assure-lock-faqs/electronic-lock-
*Requires addition of Thin Door Kit.
installation/
Setting Definitions
Privacy mode is disabled by default. When
enabled, activate Privacy mode by pressing the
privacy button for 4 seconds to put the lock in
do-not-disturb mode (all Entry Codes are
disabled).
FCC:
FCC ID : 2ABFG-YRD622BLEV1
Class B Equipment
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful Interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Ÿ
Reorient or relocate the receiving antenna.
Ÿ
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which
Ÿ
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Ÿ
Warning: Changes or modifications to this device, not expressly approved by Yale Home
could void the user's authority to operate the equipment.
Inside Lock
Industry Canada:
IC ID : 11626A-YRD622BLEV1
This Class A digital apparatus meets all requirements of the Canadian Interference
Causing Equipment Regulations.
Cet appareillage numérique de la classe A répond à toutes les exigences de
l'interférence canadienne causant des règlements d'équipement.
C
Yale Home
24/7 Product Support : 1-855-213-5841 • www.US.YaleHome.com
Yale® and Assure Lock® are registered trademarks of Yale Home. Yale Accentra™ is a trademark of Yale Home.
Other products' brand names may be trademarks or registered trademarks of their respective owners and are
Tailpiece
mentioned for reference purposes only. © Copyright 2020. All rights reserved. Reproduction in whole or in part
T = .098" (2.5mm)
without the express written permission of Yale Home is prohibited.
W = .2" (5.2mm)

Advertisement

Table of Contents
loading

Table of Contents