Yale real living Z-Wave Plus YRD622-NN-ZW3 Installation Manual page 37

Smart module
Table of Contents

Advertisement

Command Class Basic, Version 2*
* This command class requires security.
This command class is mapped to Door Lock CC:
Table 11 – Basic Mapping Overview
Basic Command
Basic Set (Value)
Basic Report (Current Value = 0x00)
Basic Report (Current Value = 0xFF)
The Basic Get Current Value, Basic Get Duration, and Basic Get Target Value are
mapped to Door Lock Operation Get and Basic Set is directly mapped to Door Lock
Operation Set where the Duration is returned as is, but the Value and Target Door
Lock State Value of the Basic Report use the following mapping:
Table 12 – Basic Report: Value
Value
0 (0x00)
1..99
(0x01...0x63)
100..253
(0x64...0xFD)
254 (0xFE)
255 (0xFF)
Level
0%
1..100%
Reserved
Unknown
100%
33
Door Lock Mapped Command
Door Lock Operation Set (Door Lock
Mode)
Door Lock Operation Report (Door Lock
Mode = 0x00)
Door Lock Operation Report (Door Lock
Mode > 0x00)
State
Off
On
Reserved
Unknown
On
Door Lock State
Unsecure
Secure
Unknown
Secure

Advertisement