Tiso T3 KCD XD Series Operation Manual

Tiso T3 KCD XD Series Operation Manual

Waist-high turnstile sweeper-hg

Advertisement

Quick Links

1
"TiSO-PRODUCTION" LTD
WAIST-HIGH TURNSTILE
SWEEPER-HG
Т3.КСD.ХD
OPERATION MANUAL
AUIA.207 OM (rev.1.2)
2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T3 KCD XD Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tiso T3 KCD XD Series

  • Page 1 "TiSO-PRODUCTION" LTD WAIST-HIGH TURNSTILE SWEEPER-HG Т3.КСD.ХD OPERATION MANUAL AUIA.207 OM (rev.1.2) 2021...
  • Page 2: Table Of Contents

    CONTENTS INTRODUCTION ................................3 1. DESCRIPTION AND OPERATION ........................5 1.1 General Information and Purpose ......................... 5 1.2 Specifications ................................ 6 1.3 Configuration and Scope of Delivery........................6 1.4 Design and operation ............................9 1.5 Instrumentation, tools and accessories ........................ 10 1.6 Description and operation of controllers as an integral component of the turnstile ..........
  • Page 3: Introduction

    INTRODUCTION This Operation Manual (hereinafter referred to as OM) covers the "SWEEPER-HG" type waist-high turnstile (hereinafter referred to as the "turnstile"). The Operation Manual contains information about design, specifications, installation for proper operation and maintenance of the turnstile. This Operation Manual is prepared in compliance with the specification requirements ТU U 28.9- 32421280- 005:2018.
  • Page 4 WARNINGS TO THE CUSTOMER ON SAFE OPERATION OF THE TURNSTILE These warnings are designed for ensuring of safety during operation of the turnstile to prevent violation of safety characteristics by improper installation or operation. These warnings are aimed at drawing attention of the customer to safety problems.
  • Page 5: Description And Operation

    1. DESCRIPTION AND OPERATION 1.1 General Information and Purpose 1.1.1 Purpose: The motorized turnstile is designed for pedestrian movement control at access points of industrial enterprises, banks, stadiums, administrative facilities etc. controlled by access control system (from proximity card readers) or manually (from manual control panel).
  • Page 6: Specifications

    1.1.3 The turnstile component identification codes are specified in Table 2. Table 2 Max. weight, Description of the turnstile Dimensions, mm, Order code Н В component Т3.КСD.PD Left-hand/right-hand cabinet Т3.КСD.SD Т3.КСD.KD 1800/1500 1435 Т3.КСD.PD.X Additional cabinet Т3.КСD.SD.X Т3.КСD.KD.X 1.1.4 The operation condition parameters according to GOST 15150-69 are specified in Table 3 Table 3 Operation conditions Parameter value for climatic modification NF4...
  • Page 7 1.3.2 Design of the single turnstile of "SWEEPER-HG-1" type The single turnstile consists of two single side cabinets (Slave and Master). The single leaf cabinet housing includes:  frame;  swing-type side pieces with locks;  top, side and bottom linings; ...
  • Page 8 1.3.6 Design and general appearance of the turnstile 1.3.6.1 The cabinet body is a frame 12 on which stainless steel side, top and bottom linings 1, 2, 6, 11, 8mm- tempered glass partition 5 are installed. Decorative lid 10 is fixed on frame from the top (lining material is defined by order).
  • Page 9: Design And Operation

    1.4 Design and operation 1.4.1 The cabinet operating mechanism The cabinet operating mechanism is shown in Figure 4. The electromagnetic brake provides reliable mechanical locking of swing leaf in closed position. 1 – access sensors; 2 – lock solenoid; 3 – glassholder shaft; 4 –...
  • Page 10: Instrumentation, Tools And Accessories

    1.5 Instrumentation, tools and accessories Dedicated tools are not required for installation of the turnstile (multi-purpose measurement instrumentation and installation tools are sufficient). 1.6 Description and operation of controllers as an integral component of the turnstile 1.6.1 Controller AUIA.206.21.20.00 1.6.1.1 Controller AUIA.206.21.20.00 is shown in Figure 5. 1.6.1.2 Description of operation The controller provides algorithm of operation of the whole turnstile.
  • Page 11 1 - ON - when command is issued, the turnstile will open for 5 seconds; - OFF - when command is issued, the turnstile will open for the time set in ACS; 2 - ON - Outputs OUT1-5 will be NC; - OFF - Outputs OUT1-5 will be O;...
  • Page 12 ALARM The turnstile goes to this mode from any above mentioned mode in case of unauthorized access attempts. Meanwhile red LED is frequently blinking (4 times per second), siren alarm is generated on the turnstile and control panel and output "OUT5" is activated on the controller card. If the turnstile was opened, then swing leaves would be closed if there were no obstacles in the closing area.
  • Page 13 Continued Table 5 ХТ1/1 1) type of output – open collector; peak voltage on privacy key 60V; 3) peak current of Output for connection of public key 250mA; audible alarm. The output is 4) resistance of active in case of unauthorized public key access (0,48÷...
  • Page 14 Table 6 Connector Signal parameters Direction Designation Purpose /Contact No and description « TO BE OPENED A» X1/1 ENTRY « TO BE OPENED В» 1) logical «0» (0  1,7) V; X1/2 ENTRY « LOCKING» 2) logical «1» (3,7  5) V; X1/3 ENTRY To be connected to microswitch...
  • Page 15: Intended Use

    2 INTENDED USE 2.1 Operation limitations 2.1.1 The turnstile must be used in the environment specified in p. 1.1.5 of this document subject to the specifications listed in section 1.2. IT IS FORBIDDEN: 1) TO MISUSE THE TURNSTILE (See section 1 "DESCRIPTION AND OPERATION"); 2) TO USE THE TURNSTILE UNEARTHED;...
  • Page 16 2.2.5 SWEEPER-HG type turnstile layout options Fig. 8 – SWEEPER-HG type turnstile layout options WARNING: The damages occurred during the turnstile transportation are not covered by the manufacturer's warranty liabilities. 2.2.6 Installation procedure 2.2.6.1 The turnstile installation procedure is as follows: 1) The package integrity to be checked prior to unpacking.
  • Page 17 2.2.6.2 Turnstile dismantling and relocation: To remove the turnstile from the pallet (see Fig. 9) you must open the side pieces. The side pieces are designed as a hinged door and are closed by locks. - Locks to be opened by key and door to be turned from both sides of cabinet (View А);...
  • Page 18 2.2.6.4 The following cables to be run to the turnstile installation site:  Power supply cable 220 V ~;  Control panel connection cable;  Access Control System connection cables, if available;  Cables between cabinets; Cables to be run in corrugated or metal pipes. SWEEPER-HG-1 SWEEPER-HG-1 Slave...
  • Page 19 Option 1 Option 2 Fig.12 – Options of cable connection between cabinets Master and Slave The length of cable free ends to be at least 1 m to provide their entry, termination and connection to the relevant terminals in the turnstile post. The cable outlet location to be aligned with the hole on the turnstile mounting plate.
  • Page 20 2.2.6.5 Installation in design position To access the fixation holes and terminal blocks it is required on both sides of cabinets: 1. - Locks to be opened by key and door to be turned (See Fig. 13); 2. - Bottom linings to removed by unscrewing screws M5-6g x14;...
  • Page 21 2.2.6.6 Turnstile connection: a) Power supply cable ~220 V to be connected (Fig. 14): - Phase L to be connected to the circuit breaker; - Neutral (N) to be connected to terminal ~220V (N); - Earth (РЕ) to be connected to earthing terminal (РЕ).
  • Page 22: Preparation For Use

    2.3 Preparation for use 2.3.1 Commissioning guidelines Prior to the turnstile energization: 1) make sure of proper connection and good condition of all connecting cables; 2) clear the turnstile’s leaf swing area from foreign particles. When mains cable of power supply unit is connected to the network the turnstile’s operating mechanism is energized: leaves are locked from rotation in both directions blocking access.
  • Page 23: Contingency Actions

    "LOCK" button Make sure that swing 9. Locked access pushed to lock access in Red LED of locked access in one panels are locked in one direction chosen direction ("A" or chosen direction is lit "B")* Both "LOCK" buttons to be Make sure that swing 10.
  • Page 24: Maintenance

    3 MAINTENANCE 3.1 General guidelines 3.1.1 Commissioning and subsequent maintenance of the turnstile to be performed only by the staff to be in charge of the turnstile.. 3.1.2 The turnstile to be serviced only by the staff having the relevant electrical safety qualification level according to the national requirements..
  • Page 25: Routine Maintenance

    4 ROUTINE MAINTENANCE 4.1 General guidelines Minor malfunctions of the turnstile are listed in Table 9 and are remedied by the customer. More complicated malfunctions are remedied by the manufacturer’s representative. IMPORTANT: INSPECTION, CLEANING, REPAIR OF THE TURNSTILE COMPONENTS TO BE PERFORMED ONLY AFTER THE TURNSTILE DEENERGIZATION ! 4.2 Possible malfunctions Possible malfunctions of the turnstile and their remedies are listed in Table 9.
  • Page 26: Adjustment Of The Zero Position Of Leaf For "Sweeper- Hg

    4.3. Adjustment of the zero position of leaf for “Sweeper- HG” 1. Press and hold RESET button (1) on the PCB.201.01.00.00 controller (Fig.18); 2. Set the glass leave (2) at the new zero position (manually close - Locked access) (Fig.17, Fig.18); Fig.
  • Page 27: Postrepair Checkout

    4.4 Postrepair checkout The turnstile performance is checked after repair according to paragraph 2.3.2 of this OM. 5 TRANSPORTATION AND STORAGE 5.1 Turnstile storage It is forbidden to subject the turnstile to jerks and impacts during storage. Transportation trolleys to be used for handling of the turnstile.
  • Page 28: Annex А Design And Dimensions Of The "Sweeper-Hg" Type Turnstile

    Annex А Design and dimensions of the "SWEEPER-HG" type turnstile Ø20 Ø 13 Figure А.1 – One-way left-hand/right-hand cabinet...
  • Page 29 Continued Annex А Design and dimensions of the "SWEEPER-HG" type turnstile Ø20 Ø13 Figure А.2 – Two-way cabinet...
  • Page 30: Annex B Control Panel And Connection Diagram

    Annex B Control panel and connection diagram 1 – control panel housing ; 5 – "FREE ACCESS" mode control button; 2 – "SINGLE ACCESS" mode control button 6 – "PANIC" mode control button; 3 – front plate; 7 – access direction LED display; 4 –...
  • Page 31 Continued Annex B Control panel and connection diagram Figure B.2 – Connection diagram of control panel AUIA.114.02.00.00...
  • Page 32: Annex C.1 Wiring Diagram Of The "Sweeper-Hg" Type Turnstile

    Annex C.1 Wiring diagram of the "SWEEPER-HG" type turnstile Sweeper-HG 2 Master/Slave AUIA 207 Rev. 2/MS Wi re s to ma ste r p a rt o f tu rn sti l e HL 4 PCB.2 0 5 .0 1 .0 5 .0 0 XS2 5 +1 2 V PCB 2 0 1 .0 1 .0 0 .0 0...
  • Page 33: Annex C.2 Wiring Diagram Of The "Sweeper-Hg" Type Turnstile

    Annex C.2 Wiring diagram of the "SWEEPER-HG" type turnstile Sweeper-HG 1 Slave AUIA 207 Rev. 2/MS Wires to master part of turnstile PCB 201.01.00.00 XS19 XS20 XS21 XS22 XS23 XS24 IN 1 GRN 1 IN 2 RED 1 Жгут ? 2 IN 3 GRN 2 IN 4...
  • Page 34: Annex C.3 Wiring Diagram Of The "Sweeper-Hg" Type Turnstile

    Annex C.3 Wiring diagram of the "SWEEPER-HG" type turnstile Sweeper-HG 1 Master AUIA 207 Rev. 2/MS HL 3 PCB.2 0 5 .0 1 .0 5 .0 0 AUIA . 2 0 6 .2 1 .2 0 .0 0 7 3 0 3 PCB 2 0 1 .0 1 .0 0 .0 0 10- 3 10- 6...
  • Page 35: Annex D.1 Diagram Of The Turnstile Connection To Access Control System (Acs)

    Annex D.1 Diagram of the turnstile connection to access control system (ACS) Relay 1 Relay 2 Door contact 1 Door contact 2 inp1 - "TO BE OPENED A" in pulse mode. When command is issued entry is activated for 5 sec. inp2- "TO BE OPENED B"...
  • Page 36: Annex D.2 Diagram Of The Turnstile Connection To Access Control System (Acs)

    Annex D.2 Diagram of the turnstile connection to access control system (ACS) inp1- " TO BE OPENED A" in pulse mode. When command is issued the input is activated for 5 sec. . inp - 2 " TO BE OPENED B" in pulse mode. When command is issued the input is activated for 5 seconds.
  • Page 37: Annex D.3 Diagram Of The Turnstile Connection To Fire Alarm (Fa)

    Annex D.3 Diagram of the turnstile connection to fire alarm (FA) inp1- " TO BE OPENED A" in pulse mode. When command is issued the input is activated for 5 sec. inp - 2 " TO BE OPENED B" in pulse mode. When command is issued the input is activated for 5 seconds.
  • Page 38: Annex D.4 Diagram Of The Turnstile Connection To Control Panel

    Annex D.4 Diagram of the turnstile connection to control panel 5 4 3 2 1...
  • Page 39 Manufacturer: LLC TiSO-PRODUCTION 14, Promyslova Street, Kyiv, 02088, Ukraine Phone: +38 (044) 291-21-11 Tel./fax: +38 (044) 291-21-02 E-mail: sales@tiso.global www.tiso.global SERVICE CENTER e-mail: service1@tiso.global Our equipment meets the requirements of European standards: EN ISO 12100: 2010; EN 614-1: 2006 + A1: 2009; EN 1037: 1995 + A1: 2008; EN 60204-1: 2006; EN 953: 1997 + A1: 2009;...