3: Specifications; 4: Installation; Before Installation - FIBARO ROLLER SHUTTER 4 Operating Manual

Hide thumbs Also See for ROLLER SHUTTER 4:
Table of Contents

Advertisement

6
3: Specifications
i
Power supply
NOTE
Rated load current
radio
frequency
of individual de-
vice must be same
Compatible load types
as your Z-Wave
controller. check
Required limit switches
information
on
Recommended external
the box or consult
your dealer if you
overcurrent protection
are not sure.
For installation in boxes
Recommended wires
Operating temperature
Ambient humidity
Radio protocol
Radio frequency band
Max. transmitting power
Range
Dimensions
(Height x Width x Depth)
Compliance with EU
directives
specIfIcatIons
100-240V~ 50/60 Hz
2A for motors with compensated power
factor (inductive loads)
m
single-phase AC motors
electronic or mechanic
10A type B circuit breaker (EU)
13A type B circuit breaker (Sweden)
Ø = 50mm, depth ≥ 60mm
cross-section area between 0.75-1.5 mm
stripped 8-9 mm of insulation
0–35°C
10–95% RH without condensation
Z-Wave (800 series chip)
EU: 868.4 MHz, 869.85 MHz
AH: 919.8 MHz, 921.4 MHz
+6dBm
up to 100m outdoors
up to 30m indoors
(depending on terrain and building
structure)
46 x 36 x 19.9 mm
RoHS 2011/65/EU
RED 2014/53/EU
4: Installation
4.1: Before installation
Connecting the device in a manner inconsistent with this
!
manual may cause risk to health, life or material damage.
Do not power the device before fully assembling it in the
mounting box,
Connect only in accordance with one of the diagram,
Install only in flush mounting boxes compliant with a relevant
national safety standards and with depth no less than 60mm,
2
Do not connect devices which are not compliant with the
specification or relevant safety standards,
Do not connect heating devices,
Do not connect SELV or PELV circuits,
Electrical switches used in installation should be compliant with the
relevant safety standards,
Length of wires used to connect the control switch should not
exceed 20m,
Connect roller blind AC motors with electronic or mechanical
limit switches only.
Notes for the diagrams:
O1 - 1st output terminal for shutter
motor
O2 - 2nd output terminal for shutter
motor
S1 - terminal for 1st switch
(used to add/remove the device)
S2 - terminal for 2nd switch
(used to add/remove the device)
N - terminals for the neutral lead (connected internally)
L - terminals for live lead (connected internally)
PROG - service button (used to add/remove the device and navigate
the menu)
ATTENTION ! Proper wiring and wire removal guidelines
Place wires ONLY into terminal slot(s) of the device.
To remove any wires, press the release button, located over the slot(s)
7
InstallatIon

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ROLLER SHUTTER 4 and is the answer not in the manual?

This manual is also suitable for:

Fgr-224