Technical data
Operable flow range
Input signal
Output signal
98
Nominal
diameter
min./max. full scale value
[in]
[mm]
28
700
30
750
32
800
36
900
Recommended measuring range
Flow limit → 109
For custody transfer, the applicable approval determines the permitted measuring
range, the pulse value and the low flow cut off.
Over 1000 : 1
In the case of custody transfer, the applicable approval determines the permitted
operable flow range.
Status input
Maximum input values
Response time
Input signal level
Assignable functions
Status input, power save mode
To activate the status input, the signal must change from low level to high level with a
maximum rise time of 10 ms and the high level must be present for at least the duration of
the response time. The input signal can then be set back to "low" again. After this, the
status input is ready for another activation.
16.4
Output
Status/pulse output
Function
Version
Recommended
Flow rate
(v ~ 0.3/10 m/s)
[gal/min]
1 900 to 60 000
2 150 to 67 000
2 450 to 80 000
3 100 to 100 000
• DC 30 V
• 6 mA
Configurable: 50 to 200 ms
• Low signal (low): DC –3 to +5 V
• High signal (high): DC 12 to 30 V
• Off
• Reset totalizers 1-3 separately
• Reset all totalizers
• Logbook entry only
Proline Promag 800 - Standard
With the order code for "Output; Input", option K: 3 outputs can be set either as a
pulse output or switch output
Proline Promag 800 - Advanced
With the order code for "Output; Input", option I: 3 outputs can be set either as a
pulse output or switch output
Passive, open collector
Proline Promag W 800
Factory settings
Pulse value
Low flow cut off
(~ 2 pulse/s)
(v ~ 0.04 m/s)
[gal]
[gal/min]
125
210
150
270
200
300
225
360