Reinstall The Cover - CommScope NOVUX SEC 100 Installation Instructions Manual

Fiber optic system
Table of Contents

Advertisement

3
3
Push the feeder fiber in one of the grooves of the foam.
4
If applicable, mark the stripping point in the middle of the fiber guidance channel. Strip the buffer tube off the fiber
and store the fiber temporarily on the tray.
Note:
For the patch application it is not required to strip the buffer tube.
Note:
The tray layout depends on the application. Please consult the correct application instructions for further
details on the fiber routing on the tray.
5
5
To close the tray, the tray should first be lifted upwards. The hinges fall into the free openings.
6
Turn the tray towards the bottom cover.
7
Tray closed with the feeder fiber routed to the tray.
9

Reinstall the cover

1
1
Reinstall the tray cover.
2
Mount the cover on the bottom by sliding the hinges into the cavities.
3
A clicking sound is observed.
4
S tripping point
6
2
page 12 / 14
© 2022 CommScope, Inc. All Rights Reserved
7
3
CLICK