About this manual

This manual describes the installation steps of the drop splice application of the SEC 100 series. Installation steps in this
document are limited to: drop cable installation (push through), routing on and to the different trays, splicing on the
different trays and the splitter application.
Installation steps of the inline feeder cable are explained in manual TC-1557-IP: SEC 100 Basic Instructions. The
document starts with providing an overview of the tools required to perform the installation. Also warnings and
cautions are indicated, which should be observed before starting the product installation.
Images in this manual are for reference only and are subject to change.
2

Cable range drop cable

Drop cable (Push through)
3

Tools

• Cable stripping and cleaning tools
• Cable tie gun (optional) or small side cutter (to cut excess cable tie)
• Fiber splice equipment and fiber cleaning tools
• Scissors (to cut the silicon tape)
4

Warnings and Cautions

• Follow the installation instruction steps to ensure the performance of the closure. It is necessary to take
precautions and keep the working space clean to protect the closure sealing materials and splices.
• Exposure to laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical
fiber. Do not assume the laser power is turned off or that the fiber is disconnected at the other end. Looking into
the ends of any optical fiber is entirely at your own risk. A protective cap or hood MUST be immediately placed
over any radiating adapter or optical fiber connector to avoid the potential of dangerous amounts of radiation
exposure. This practice also prevents dirt particles from entering the connector and adapter.
• Fiber optic cables may be damaged if bent or curved to a radius that is less than the recommended minimum bend
radius. Always observe the recommended bend radius limit when installing fiber optic cables, subunits and patch
cords.
All trademarks identified by ® are registered trademarks in the US and may be registered in other countries. All third party product names, trademarks and
registered trademarks are property of their respective owners. This product may be covered by one or more U.S. patents or their foreign equivalents. For
patents, see www.cs-pat.com. This document is not intended to modify or supplement any specifications or warranties relating to CommScope products or
services. Visit our website or contact your local CommScope® representative for more information. www.commscope.com.
For technical assistance, customer service, or to report any missing/damaged parts, visit us at: http://www.commscope.com/SupportCenter.
NOVUX™ Fiber Optic System
SEC 100 Splice Application
Cable range (mm)
3-7
© 2022 CommScope, Inc. All Rights Reserved
Installation Instructions
Position in closure
2, 3, 4
page 1 / 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NOVUX SEC 100 and is the answer not in the manual?

Questions and answers

Summary of Contents for CommScope NOVUX SEC 100

  • Page 1 This product may be covered by one or more U.S. patents or their foreign equivalents. For patents, see www.cs-pat.com. This document is not intended to modify or supplement any specifications or warranties relating to CommScope products or services.
  • Page 2 Make sure to push through enough cable to be able to strip the cable. Strip the cable per local practice over a length of 130 cm. Clean the 900µm fiber per local practice. Align the cable jacket with the cable bracket. page 2 / 6 © 2022 CommScope, Inc. All Rights Reserved...
  • Page 3 For the drop cable installed in position 4, guide the 900 µm around the island and enter the tray as shown. page 3 / 6 © 2022 CommScope, Inc. All Rights Reserved...
  • Page 4 Indicate the stripping point in the middle of the fiber guide and strip the buffer tube of the fiber per local practice. Note: Note that the fiber from the drop cable can enter the tray either at the same side of the feeder fiber or the opposite side. page 4 / 6 © 2022 CommScope, Inc. All Rights Reserved...
  • Page 5 Make sure all fibers are properly positioned under the lips and avoid bulging of the fiber. Note: The fiber guidance pen can be used to position all the fibers under the lips. page 5 / 6 © 2022 CommScope, Inc. All Rights Reserved...
  • Page 6 Make sure all fibers are properly positioned under the lips and avoid bulging of the fiber. Note: The fiber guidance pen can be used to position all the fibers under the lips. page 6 / 6 © 2022 CommScope, Inc. All Rights Reserved...

Table of Contents