TC-1557-IP-PA Rev. A, December 2022
1

About this manual

This manual describes the installation steps of the patch application of the SEC 100 series. Installation steps in this
document are limited to: splicing input of the connectors to the feeder fibers, patching SC cables and patching LC
cables.
Installation steps of the inline feeder cable are explained in manual TC-1557-IP: SEC 100 Basic Instructions. The
document starts with providing an overview of the tools required to perform the installation. Also warnings and
cautions are indicated, which should be observed before starting the product installation.
Images in this manual are for reference only and are subject to change.
2

Cable range patch cable

Connectorized drop cable (slit in rubber seal)
3

Tools

• Cable stripping and cleaning tools
• Cable tie gun (optional) or small side cutter (to cut excess cable tie)
• Fiber splice equipment and fiber cleaning tools
• Scissors (to cut the silicon tape)
4

Warnings and Cautions

• Follow the installation instruction steps to ensure the performance of the closure. It is necessary to take
precautions and keep the working space clean to protect the closure sealing materials and splices.
• Exposure to laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical
fiber. Do not assume the laser power is turned off or that the fiber is disconnected at the other end. Looking into
the ends of any optical fiber is entirely at your own risk. A protective cap or hood MUST be immediately placed
over any radiating adapter or optical fiber connector to avoid the potential of dangerous amounts of radiation
exposure. This practice also prevents dirt particles from entering the connector and adapter.
• Fiber optic cables may be damaged if bent or curved to a radius that is less than the recommended minimum bend
radius. Always observe the recommended bend radius limit when installing fiber optic cables, subunits and patch
cords.
All trademarks identified by ® are registered trademarks in the US and may be registered in other countries. All third party product names, trademarks and
registered trademarks are property of their respective owners. This product may be covered by one or more U.S. patents or their foreign equivalents. For
patents, see www.cs-pat.com. This document is not intended to modify or supplement any specifications or warranties relating to CommScope products or
services. Visit our website or contact your local CommScope® representative for more information. www.commscope.com.
For technical assistance, customer service, or to report any missing/damaged parts, visit us at: http://www.commscope.com/SupportCenter.
NOVUX™ Fiber Optic System
SEC 100 Patch Application
Cable range (mm)
3 - 6
© 2022 CommScope, Inc. All Rights Reserved
Installation Instructions
2,3,4,5
Position in closure
page 1 / 7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NOVUX SEC 100 and is the answer not in the manual?

Questions and answers

Summary of Contents for CommScope NOVUX SEC 100

  • Page 1 This product may be covered by one or more U.S. patents or their foreign equivalents. For patents, see www.cs-pat.com. This document is not intended to modify or supplement any specifications or warranties relating to CommScope products or services.
  • Page 2 Install the inline feeder cable as explained in document TC-1557-IP. Slide the patch panel in its first lock as shown. Rotate the patch panel so its second locking feature falls into the hole at the top side. page 2 / 7 © 2022 CommScope, Inc. All Rights Reserved...
  • Page 3 Tray installed and locked into the bottom. Connect the output of the splitter to the patch panel Remove the cover of the tray and guide the output of the splitter to the patch panel. page 3 / 7 © 2022 CommScope, Inc. All Rights Reserved...
  • Page 4 Remove the dust caps of both the adapter and the connector. Clean per standard practice. Position the connector in the correct orientation (clip facing upward as shown in figure above). page 4 / 7 © 2022 CommScope, Inc. All Rights Reserved...
  • Page 5 Make sure all fibers are properly positioned under the lips and avoid bulging of the fiber. Note: The fiber guidance pen can be used to position all the fibers under the lips. page 5 / 7 © 2022 CommScope, Inc. All Rights Reserved...
  • Page 6 50% while wrapping the tape around the cable. First apply a full turn around the cable, then continue to cover up. Secure the cable with a black cable tie at the outside T-shape over the silicon tape. Make sure at the bottom side it grips in the recess. page 6 / 7 © 2022 CommScope, Inc. All Rights Reserved...
  • Page 7 50% while wrapping the tape around the cable. First apply a full turn around the cable, then continue to cover up. Secure the cable with a black cable tie at the outside T-shape over the silicon tape. Make sure at the bottom side it grips in the recess. page 7 / 7 © 2022 CommScope, Inc. All Rights Reserved...

Table of Contents