Control / Operation; Connections; Switching On The Cleaner - Nilfisk-Advance MH 7P Instructions For Use Manual

Table of Contents

Advertisement

4 Control / Operation

4.1

Connections

4.1.1 Connecting the spray
lance to the spray gun
4.2
Switching on the
cleaner
4.2.1 Cold water operation /
Hot water operation (up
to 100°C)
1)
Options / model variants
Original instruction
A
C
B
NOTE!
Always remove any dirt from
the nipple before connecting the
spray lance to the spray gun.
0
I
M
1. Pull the blue quick-release
grip (A) of the spray gun for-
wards and lock it by turning it
to the left.
2. Insert the nipple of the spray
lance (C) into the quick-re-
lease connection and turn the
blue quick-release grip to the
right (B).
3. Pull the spray lance (or other
accessory) forwards to check
that it is securely attached to
the spray gun.
1. Turn the main switch to posi-
tion
(cold water).
Control electronics accomplishes
a self check.
The Display shows for approx. 1
second „---".
The motor starts.
is ON.
2. Turn the main switch to posi-
tion
(hot water).
3. Select temperature.
4. Unlock the spray gun and
squeeze trigger.
5. The oil burner will light.
6. Release trigger and lock the
spray gun when not in use.
NOTE!
The cleaner switches off auto-
matically twenty seconds after
the spray gun has been closed. To
start the cleaner again, squeeze
the trigger and the machine will
start automatically.
english