Nilfisk-Advance MH 1C Instructions For Use Manual

Nilfisk-Advance MH 1C Instructions For Use Manual

Advertisement

MH 1C - MH 2C - MH 2M -
Instructions for use
107145403 F (09. 2016)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MH 1C and is the answer not in the manual?

Questions and answers

Summary of Contents for Nilfisk-Advance MH 1C

  • Page 1 MH 1C - MH 2C - MH 2M - Instructions for use 107145403 F (09. 2016)
  • Page 2 12 13 14 15 16 17 °F °C CUT OUT 60 140 70 160...
  • Page 3 ............................4 ............................20 ............................36 ............................52 ............................68 ............................84 ............................100 ............................116 ............................132 ............................148 ............................164 ............................180 ............................196 ............................213 ............................229 ............................245 ............................261 ............................277 ............................293 ............................309 ............................328 ............................
  • Page 4: Table Of Contents

    Switching off the cleaner and disconnecting supply lines ............. 14 Rolling up the electrical lead and storing accessories............14 MH 1C Storing the cleaner (below 0°C) ................14 MH 2C/MH 2M Storing the cleaner (below 0°C) ..............15 Transporting the cleaner ....................... 15 7 Maintenance ............................
  • Page 5: Safety Instructions

    Safety instruc- Symbols used to mark This indicates t i o n s i n t h e s e tips and instruc- instructions operating instruc- tions to simplify tions which must work and to en- be observed to sure safe operation. prevent risks to persons are marked with this danger symbol.
  • Page 6: Description

    MH 1C is for light professional use only. 1. High pressure hose reel 11. Control panel Operating elements 2.
  • Page 7: Before Starting The Cleaner

    3 Before starting the cleaner Setting up the cleaner Every fuel-burning appliance, formance before it left our fac- such as pressure washers, de- tory. The factory is located at ap- pends upon a proper mix of fuel proximately 140m (450 ft) above and air (by weight) for proper sea level, and the combustion combustion.
  • Page 8: Fill Up Fuel Tank

    Fill up fuel tank With the machine cold: NOTE! Fill fuel tank from a clean con- At temperatures below 8° C, the fuel tainer with a fresh fuel, heating oil begins to solidify (paraffin precip- oil, DIN 51603-1 (without bio itation).
  • Page 9: Electrical Connection

    CAUTION! 1. Observe safety instructions in Electrical connection When using cable reels: chapter 1. 1. Due to the risk of overheat- 2. Put the plug into the electrical ing and fire, always unwind socket. the power supply cord fully. The cleaner may only be con- nected to a correctly installed electrical installation.
  • Page 10: Control / Operation

    4 Control / Operation Switching on the 1. Move the main switch into cleaner position 'Cold Water' (A) The control electronics sys- tem performs a self-test, all the LEDs light up once. The motor starts lights up. NOTE! 2. Ventilate the machine for air Always remove any dirt from the nipple before connecting the spray by activating the spray gun...
  • Page 11: Pressure Regulation (Ergo Vario Press Gun) 1)

    The trigger must be free to close when released, thus interrupting the flow of the water. Using cleaning agents MH 1C Cleaning agent can be drawn in via the injector installed as standard only in low-pressure mode: 1.
  • Page 12: Applications And Methods

    5 Applications and methods Effi cient high pressure cleaning is achieved by following a few Techniques guidelines, combined with your own personal experience of specifi c cleaning tasks. Accessories and detergents, when correctly chosen, can increase the effi ciency of your pressure washer. Here is some basic information about cleaning.
  • Page 13 5.2.2 Vehicle Task Accessories Method Vehicle bodywork Standard lance 1. Apply detergent to vehicle or equipment surfaces in Detergent injection order to soften up dirt and grime. Apply from bottom Curved lances and un- to top. In cases of particularly dirty vehicles, pre-spray derchassis washers with a product such as Allosil in order to remove traces brushes...
  • Page 14: After Using The Cleaner

    Place the spray lance into the storage position. MH 1C Store the cleaner in a dry room against frost when antifreeze Storing the cleaner without danger of frost or protect solution emerges from the (below 0°C)
  • Page 15: Mh 2C/Mh 2M Storing The Cleaner (Below 0°C)

    Store the cleaner in a dry room MH 2C/MH 2M against frost when antifreeze without danger of frost or protect Storing the cleaner solution emerges from the as below: spray gun. (below 0°C) 9. Lock the safety catch on the 1.
  • Page 16: Maintenance

    7 Maintenance Maintenance plan Maintain water filters and fuel fil- ters as required. Maintenance work A water fi lter is fi tted on the water 7.2.1 Water filters inlet to prevent large particles of dirt from entering into the pump. 1.
  • Page 17: Troubleshooting

    7.2.4) sooted > Contact Nilfi sk Service - Ignition or fuel system > Cold water operation is pos- failure sible Options / model variants Original instruction MH 2C/MH 2M For MH 1C only. For overheating warning see next page.
  • Page 18: Other Faults

    Indication lights Cause Remedy > No indication and main • Turn main switch to position switch is on “OFF“ - let the machine cool - Motor is overheated down Remove/disconnect extension cable Possible phase failure on 3 phase variants : have electri- cal connection checked Contact Nilfi...
  • Page 19: Further Information

    DK-2605 Broendby DENMARK Hereby declare that the Products: HPW - Professional - Mobile - El Description: 230V/50Hz, 400V/3~/50Hz, IPX5 Type: MH 1C*, MH 2C*, MH 2M* Are in compliance with the following standards: EN 60335-1:2012+A11:2014 EN 60335-2-79:2012 EN 55014-1:2006+A1:2009+A2:2011 EN 55014-2:2015...
  • Page 20: Specifications

    Specifications MH 1C-110/600 MH 1C-110/600 MH 2C-90/670 X MH 2C-145/600 V/ph/Hz 230/1/ 50 230/1/ 50 230/1/ 50 230/1/ 50 C 16 C 13 C 13 C 16 кВт 12,4 14,5 bar (MPa) Бар (МПа) 巴(兆帕) l/min л/мин 10,7 升/分钟 bar (MPa) Бар...
  • Page 21 Specifications MH 2C-145/600 X MH 2M-140/600 MH 2M-140/600 X MH 2M-155/660 V/ph/Hz 230/1/ 50 230/1/ 50 230/1/ 50 400/3/50 C 16 C 16 C 16 C 16 кВт 14,5 14,5 14,5 bar (MPa) Бар (МПа) 巴(兆帕) l/min л/мин 10,0 升/分钟 bar (MPa) Бар...
  • Page 22 Specifications MH 2M-155/660 X MH 2C-170/690 MH 2C-170/690 X MH 2C-170/690 X V/ph/Hz 400/3/50 400/3/50 400/3/50 230/400/3/50 C 16 C 16 C 16 C 16 кВт 14,3/8 bar (MPa) Бар (МПа) 巴(兆帕) l/min л/мин 10,0 10,5 10,5 10,5 升/分钟 bar (MPa) Бар...
  • Page 23 Specifications MH 2C-190/780 MH 2C-190/780 X MH 2C-125/600 MH 2C-145/600 V/ph/Hz 400/3/50 400/3/50 220/1/60 240/1/50 C 16 C 16 C 16 C 15 кВт 14,3 14,5 bar (MPa) Бар (МПа) 巴(兆帕) l/min л/мин 12,2 12,2 升/分钟 bar (MPa) Бар (МПа) 巴(兆帕)...
  • Page 24 Specifications MH 2C-100/450 V/ph/Hz 240/1/50 C 10 кВт bar (MPa) Бар (МПа) 巴(兆帕) l/min л/мин 升/分钟 bar (MPa) Бар (МПа) 巴(兆帕) l/min 25030 °C (°F) 90/150 °C (°F) bar (MPa) Бар (МПа) 巴(兆帕) 607/688/1000 毫米 кг dB(A) дБ(A) = 3 dB dB(A) 89,5 дБ(A)
  • Page 25 EN: Country variant. DE: Ländervarianten. FR: Selon le pays. NL: Nationale variant. IT: Variante per il Paese. NO: Variant i ulike land. SV: Landsvariant. DA: Landespecifik variant. FI: Maakohtainen vaihtelu. ES: Depende del país. PT: Variante do país. EL: Έκδοση χώρας. TR: Ülkedeki model. SL: Jeziko- vna različica.
  • Page 26 EN: Water flow. DE: Wasserdurchsatz. FR: Débit d‘eau. NL: Waterdoorstro- ming. IT: Flusso dell‘acqua. NO: Vanntilførsel. SV: Vattenflöde. DA: Vand- mængde. FI: Vedenvirtaus. ES: Flujo de agua. PT: Fluxo de água. EL: Ροή l/min νερού. TR: Su akışı. SL: Pretok vode. HR: Regulacija protoka vode. SK: л/мин...
  • Page 27 EN: Max water inlet temperature, Intake-Pressure operation. DE: Max Wassereinlasstemperatur - Druckbetrieb. FR: Température max. de l‘entrée d‘eau en mode admission/pression. NL: Max. Waterinlaattempe- ratuur Inlaat-Tijdens. Bedrijf. IT: Temperatura max. alimentazione acqua Funzionamento a ingressopressione. NO: Maks. temperatur vanninntak, Inntakstrykk drift. SV: Max ingående vattentemperatur inlopps-tryckdrift. DA: Maks.
  • Page 28 EN: Sound pressure level L . DE: Schalldruckpegel FR: Niveau de pres- sion acoustique NL: Geluidsdrukniveau IT: Livello pressione sonora NO: Lydtrykknivå SV: Ljudtrycksnivå DA: Lydtryksniveau FI: Äänenpainetaso ES: Nivel de presión sonora PT: Nível de pressão acústica EL: Επίπεδο πίεσης ήχου...
  • Page 29 EN: Fuel tank. DE: Kraftstofftank. FR: Réservoir de carburant. NL: Brandstoftank. IT: Serbatoio carburante. NO: Drivstoffbeholder. SV: Bränsle- tank. DA: Brændstoftank. FI: Polttoainesäiliö. ES: Depósito de combustible. PT: Depósito de combustível. EL: Ρεζερβουάρ καυσίμου. TR: Yakıt depo- л su. SL: Posoda za gorivo. HR: Spremnik goriva. SK: Palivová nádrž. CS: 升...
  • Page 30 HEAD QUARTER GERMANY PERU TURKEY Nilfi sk GmbH Nilfi sk S.A.C. Nilfi sk A.S. DENMARK Guido-Oberdorfer-Straße 2-10 Calle Boulevard 162, Of. 703, Lima 33- Serifali Mh. Bayraktar Bulv. Sehit Sk. No:7 Nilfi sk A/S 89287 Bellenberg Perú Ümraniye, 34775 Istanbul Kornmarksvej 1 Tel.: (+49) (0)7306/72-444 Lima...

This manual is also suitable for:

Mh 2mMh 2c

Table of Contents