BenQ VL3735 Service Manual page 36

Hide thumbs Also See for VL3735:
Table of Contents

Advertisement

output voltage
Is in 1.2.2 range.
Step load : changed for a 25% step load.
The slew rate of load change: 1A per microsecond.
Duty of step load: 50%
Transient frequency range: 100Hz to 1KHz
2.9.2.8 Protection
2.9.2.8.1 Over Voltage
2.9.2.8.2 Over Current
2.9.2.8.3 Short Circuit
The power supply is protected that a short happened between the output terminals
and shall
not result in a fire hazard.
2.9.3 Power Management:
PC power saving
Normal operation
Protection
Over Voltage
Meet 2.10 Safety regulation.
Over Current
Meet 2.10 Safety regulation.
Short Circuit
Meet 2.10 Safety regulation.
Meet Safety regulation.
Meet Safety regulation.
And OCP set as following:
5VS: without OCP, but output do not over 12A.
5V: without OCP, but output do not over 12A.
12V: without OCP, but output do not over 8A.
24V: 10 ~ 12A
Power Consumption
Mode
Standby
220 W (Max.)
(AC220V)
<5W
<15W
36
LED Color
Red
Flash
Green

Advertisement

Table of Contents
loading